      <title-group><article-title>Reflection of ground-source heat pump systems' application</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Zhang</surname><given-names>Suyun</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Lin</surname><given-names>Zhenguo</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Wu</surname><given-names>Xiangsheng</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Wu</surname><given-names>Tian</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">Department of Architecture and Environment, Logistical Engineering University, Chongqing, 400041, P.R. China</aff>
      <aff id="aff2">Colleges of Urban Construction and Environmental Engineering, Chongqing University, Chongqing 400045, P.R.China</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>24</day><month>10</month><year>2003</year></pub-date>
      <volume>2</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-1-995850-10-8</isbn>
      <fpage>104</fpage>
      <lpage>106</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2003.024"/>
      <permissions>
        <copyright-statement>© 2003 Copyright WSSET</copyright-statement>
        <copyright-year>2003</copyright-year>
      </permissions>
      <abstract><p>Ground-source heat pump system is an air-conditioning form of energy efficient and environment protection. This article introduced the forms of ground-source heat pump systems, analyzed the problems of ground-source heat pump systems in application in China, and put forward the solutions to these problems.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>ground-source heat pump</kwd>
        <kwd>system forms</kwd>
        <kwd>problems</kwd>
        <kwd>solution</kwd>
      </kwd-group>
      <conference>
        <conf-date>24 to 27 October 2003</conf-date>
        <conf-name>2nd International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2003</conf-acronym>
        <conf-num>2</conf-num>
        <conf-loc>Chongqing, China</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">Yan,aibin. Technique analysis and reflection of ground-source heat pump system Tianjing city construction faculty transaction, 2002,vol8, p120~122</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">Li xianrui, Liu xiao, water-source heat pump and not utilized energy. HVAC 2000 transaction, p122~126</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>