<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2004.007</article-id>
      <article-id pub-id-type="publisher-id">2004.007</article-id>
      <title-group><article-title>Computational investigation on the performance and parameter matching of ejectors in bi-ejector refrigeration system</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Shen</surname><given-names>Shengqiang</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Qu</surname><given-names>Xiaoping</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Zhang</surname><given-names>Bo</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Li</surname><given-names>Haijun</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">Department of Power Engineering, Dalian University of Technology, Dalian 116024, China</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>28</day><month>06</month><year>2004</year></pub-date>
      <volume>3</volume>
      <isbn publication-format="electronic">978-1-995850-06-1</isbn>
      <fpage>1</fpage>
      <lpage>5</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2004.007"/>
      <history>
        <date date-type="received"><string-date>28 June 2004</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2004 Copyright WSSET</copyright-statement>
        <copyright-year>2004</copyright-year>
      </permissions>
      <abstract><p>A design of bi-ejector refrigeration system was presented by the authors. In the system there are two ejectors: one is to suck refrigerant steam from evaporator and discharge to condenser, the other is a jet pump which pumps liquid refrigerant from condenser to generator. With numerical computation, the two aspects are investigated: (1) the flow characteristics of flow field in ejector. (2) the matching characteristics of the two ejectors. The simulation shows that the discharge pressure of jet-pump could be higher than that of motive steam with proper entrainment ratio. On the given refrigeration condition, the higher the generator pressure, the lower the entrainment ratio of steam-liquid ejector, but the entrainment ratio of steam-steam ejector is higher. With suitable matching parameters of two ejectors, the optimal COP of the system could be achieved.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>ejector</kwd>
        <kwd>refrigeration</kwd>
        <kwd>bi-ejector refrigeration system</kwd>
        <kwd>entrainment ratio</kwd>
      </kwd-group>
      <conference>
        <conf-date>28 to 30 June 2004</conf-date>
        <conf-name>3rd International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2004</conf-acronym>
        <conf-num>3</conf-num>
        <conf-loc>Nottingham, United Kingdom</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>