<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2004.008</article-id>
      <article-id pub-id-type="publisher-id">2004.008</article-id>
      <title-group><article-title>Field Tests of a Novel Ventilation Cooling System for Reducing Air Conditioning in Buildings</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Etheridge</surname><given-names>David</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Murphy</surname><given-names>Kevin</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">School of the Built Environment, University of Nottingham, Nottingham, UK</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>28</day><month>06</month><year>2004</year></pub-date>
      <volume>3</volume>
      <isbn publication-format="electronic">978-1-995850-06-1</isbn>
      <fpage>1</fpage>
      <lpage>5</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2004.008"/>
      <history>
        <date date-type="received"><string-date>28 June 2004</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2004 Copyright WSSET</copyright-statement>
        <copyright-year>2004</copyright-year>
      </permissions>
      <abstract><p>Air conditioning is now seen as a new and major contributor to CO2 emissions in the UK. This is partly due to global warming and partly to the increased use of IT systems. A novel system for reducing or eliminating the need for air conditioning was developed to the proof-of-concept stage under an earlier project at the University of Nottingham. The present paper describes field tests on the system that have recently been completed and which demonstrate the effectiveness of the system under real operating conditions. Systems were installed in two offices and detailed monitoring of their performance was carried out during the summer months. On the basis of the results obtained it is concluded that the system functions very well and is practically and technically the most attractive of the available alternatives to air conditioning. The fact that it is suited to retrofitting in existing buildings means that both the potential market and the CO2 reductions are large.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>CO2</kwd>
        <kwd>cooling</kwd>
        <kwd>heat pipe</kwd>
        <kwd>PCM</kwd>
        <kwd>natural ventilation</kwd>
        <kwd>air conditioning</kwd>
      </kwd-group>
      <conference>
        <conf-date>28 to 30 June 2004</conf-date>
        <conf-name>3rd International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2004</conf-acronym>
        <conf-num>3</conf-num>
        <conf-loc>Nottingham, United Kingdom</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>