<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2004.013</article-id>
      <article-id pub-id-type="publisher-id">2004.013</article-id>
      <title-group><article-title>School of Hard Rocks: Lessons out of Africa</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Rainbow</surname><given-names>Mike</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>mike.rainbow@arup.com</email>
      </contrib>
      <aff id="aff1">Arup, Nottingham, UK</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>28</day><month>06</month><year>2004</year></pub-date>
      <volume>3</volume>
      <isbn publication-format="electronic">978-1-995850-06-1</isbn>
      <fpage>1</fpage>
      <lpage>6</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2004.013"/>
      <history>
        <date date-type="received"><string-date>28 June 2004</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2004 Copyright WSSET</copyright-statement>
        <copyright-year>2004</copyright-year>
      </permissions>
      <abstract><p>The design of Harare International School in Zimbabwe generated a number of pioneering appropriate technologies of broader relevance. The most important of these are: • passive cooling of room supply air using buried rockstore compartments • passive ventilation using unique wind-driven fans Peak supply air passive cooling of up to 10°C (or 2/3rds of the diurnal swing) has been achieved through the rockstore scheme without impacting on system fan power requirements. The self-regulating wind-driven extractors achieve static pressure generation several orders of magnitude higher than other passive ventilation techniques, facilitating a greater range of passive ventilation applications than previously feasible. The scheme phases were delivered at capital costs less than that required for conventional air-conditioned schemes in Zimbabwe and required minimal amounts of scarce hard-currency. Energy costs in use are less than 10% of conventional and maintenance costs are also significantly reduced. Resource-efficient design was key to minimising both environmental and financial cost. Use of local materials and skills was crucial to achieving a robust and sustainable solution. Embodied energy, water and emissions/pollution are all minimised through this approach.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>rockstores</kwd>
        <kwd>passive cooling</kwd>
        <kwd>wind-assisted ventilation</kwd>
        <kwd>appropriate technology</kwd>
        <kwd>Zimbabwe</kwd>
      </kwd-group>
      <conference>
        <conf-date>28 to 30 June 2004</conf-date>
        <conf-name>3rd International Conference on Sustainable Energy Technologies</conf-name>