      <article-id pub-id-type="doi">10.65582/set.2004.019</article-id>
      <article-id pub-id-type="publisher-id">2004.019</article-id>
      <title-group><article-title>Graphic model study of combining different modes of heating and air conditioning</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Li</surname><given-names>Yonghong</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>liyonghong02@mails.tsinghua.edu.cn</email>
      </contrib>
      <aff id="aff1">Department of Building Science &amp; Technology, Tsinghua University, Beijing, China</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>28</day><month>06</month><year>2004</year></pub-date>
      <volume>3</volume>
      <isbn publication-format="electronic">978-1-995850-06-1</isbn>
      <fpage>1</fpage>
      <lpage>5</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2004.019"/>
      <history>
        <date date-type="received"><string-date>28 June 2004</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2004 Copyright WSSET</copyright-statement>
        <copyright-year>2004</copyright-year>
      </permissions>
      <abstract><p>This paper investigates the capacity configuration of several typical heating and cooling modes. And it uses a graphic methodology to gain the proportion of capacity to meet with heating and cooling loads which considers the difference of initial investment and operating costs. It also considers the load characteristics and the variation of equipment performance.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>capacity configuration</kwd>
        <kwd>initial investment</kwd>
        <kwd>operating costs</kwd>
        <kwd>load characteristics</kwd>
      </kwd-group>
      <conference>
        <conf-date>28 to 30 June 2004</conf-date>
        <conf-name>3rd International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2004</conf-acronym>
        <conf-num>3</conf-num>
        <conf-loc>Nottingham, United Kingdom</conf-loc>
      </conference>