<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2005.047</article-id>
      <article-id pub-id-type="publisher-id">2005.047</article-id>
      <title-group><article-title>The Application and Analysis Method of Air-Condition System for Inner Zone</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Li</surname><given-names>Deying</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Li</surname><given-names>Jinsha</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Fan</surname><given-names>Yun</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">Beijing Institute of Civil Engineering and Architecture, Beijing, China</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>23</day><month>09</month><year>2005</year></pub-date>
      <volume>4</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-7-112-07718-2</isbn>
      <fpage>211</fpage>
      <lpage>214</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2005.047"/>
      <history>
        <date date-type="received"><string-date>23 September 2005</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2005 Copyright WSSET</copyright-statement>
        <copyright-year>2005</copyright-year>
      </permissions>
      <abstract><p>The article discusses the problem about how to effectually dispel the surplus heat of the inner zone with many ways. The inner zone is the least in the winter and is the most in the transitional season. The area between the least inner zone and the most is defined cushion zone. The second, discussing the reasonable setting of the cold source, the specialties of the typical inner air-conditioning system, and the limit of all the system. Three types of inner air conditioning systems have been analyzed emphatically in the article from the system design and the operation control. According to an actual project, we compare theses three systems in the aspect of economy operation.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Inner zone</kwd>
        <kwd>Buffer</kwd>
        <kwd>Open big room</kwd>
        <kwd>Variable volume system</kwd>
      </kwd-group>
      <conference>
        <conf-date>23 to 25 September 2005</conf-date>
        <conf-name>4th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2005</conf-acronym>
        <conf-num>4</conf-num>
        <conf-loc>Jinan, China</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">Pan Yungang. Air conditioning design of high-rise civil building. China Architecture Industry Press.2003</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">Fu Xiangzhao. Building energy saving technology in hot summer and cold winter area. China Architecture Industry Press.1999</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">John Burnnett, Wang Sheng Wei. Energy use in large air-conditioned building in Hong Kong. Energy and Environment proceedings of International conference on Energy and Environment, ICEE 1996</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">Fan Cunyang. Air conditioning design and project of large space building. China Architecture Industry Press.2001</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">Xue Zhifeng. Reports on test of VAV air conditioning system of Develop Building. 1998</mixed-citation>
      </ref>
      <ref id="ref-r6">
        <mixed-citation publication-type="journal">Pan Yungang. Air Conditioning System Design of the Beijing Nanyin Building. HV&amp;AC. March 1999.Vol.29. 58~60</mixed-citation>
      </ref>
      <ref id="ref-r7">
        <mixed-citation publication-type="journal">Fan Cunyang. Advancement in air conditioning technology focusing on human health and comfort, environment protection and energy efficiency. HV&amp;AC. 1999(2)</mixed-citation>
      </ref>
      <ref id="ref-r8">
        <mixed-citation publication-type="journal">Ma Zuiljang, Sun Yuhui. Free cooling by cooling tower. HV&amp;AC. 1998(6) 8.</mixed-citation>
      </ref>
      <ref id="ref-r9">
        <mixed-citation publication-type="journal">Ted Pannkoke: Cooling tower basic. Heating/Piping/Air Condition,1996</mixed-citation>
      </ref>
      <ref id="ref-r10">
        <mixed-citation publication-type="journal">Long Weiding. China’s energy structure and trends in heating/cooling source selection. HV&amp;AC.2002(5)</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>
