<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2005.101</article-id>
      <article-id pub-id-type="publisher-id">2005.101</article-id>
      <title-group><article-title>Temperature Characteristics of Cascade Refrigeration System by Adjusting Compressor Inlet Pressure</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Kim</surname><given-names>Yeong Geun</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Rahadiyan</surname><given-names>Lubi</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Kim</surname><given-names>Bo Han</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Jeong</surname><given-names>Hyo Min</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Chung</surname><given-names>Han Shik</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
      </contrib>
      <aff id="aff1">Graduate School, Dept. of Mechanical and Precision Engineering, Gyeongsang National University, Tongyeong, KOREA</aff>
      <aff id="aff2">School of Mechanical and Aerospace Engineering, Gyeongsang National University, Tongyeong, KOREA</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>23</day><month>09</month><year>2005</year></pub-date>
      <volume>4</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-7-112-07718-2</isbn>
      <fpage>455</fpage>
      <lpage>459</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2005.101"/>
      <history>
        <date date-type="received"><string-date>23 September 2005</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2005 Copyright WSSET</copyright-statement>
        <copyright-year>2005</copyright-year>
      </permissions>
      <abstract><p>This paper present the development and testing of cascade refrigerator system for achieving super-low temperature condition. This experiment study effect of pressure in the second stage compressors inlet to the temperature distribution characteristics of the cascade refrigeration system. Compressor inlet pressure of low-pressure stage was tested in the vacuum condition and over-atmospheric pressure. Two different types of refrigerants are utilized for this system, R-22 is applied for the high stage, and R-23 for the low-pressure stage. The lowest temperature in the low-pressure evaporator, which can be achieved by this cascade refrigeration system, is down to −85 °C.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Cascade Refrigeration System</kwd>
        <kwd>High Pressure Stage</kwd>
        <kwd>Low Pressure Stage</kwd>
        <kwd>Variable Expansion Valve</kwd>
      </kwd-group>
      <conference>
        <conf-date>23 to 25 September 2005</conf-date>
        <conf-name>4th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2005</conf-acronym>
        <conf-num>4</conf-num>
        <conf-loc>Jinan, China</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">Method of Efficiency test, KS B 6366, 2002.6.20, Korea Standard Association, freezing chapter.</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">Proper form temperature condition of compressor for refrigerator, KS B 6266, 2001.9.15, Korea Standard Association</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">Method of Condensing unit examination, KS B 6333, 1992, Korea Standard Association</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">Guidance for Creation Pressure-Enthalpy about Various Refrigerants</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">Ohugyu, 1994, &quot;Re-evaluation of Ammonia as a Refrigerant&quot; air conditioning freezing engineering emperor 23 book No. 4, pp . 314~325 . (13) Namimu, 1995, &quot;NON-CFC freezing machine development same native place&quot; freezing mutual assistance technology August number, pp . 93~103 .</mixed-citation>
      </ref>
      <ref id="ref-r6">
        <mixed-citation publication-type="journal">McLinden, M., 1998, NIST Thermodynamic Properties and Refrigerant Mixtures Database 23(REFPROP), Version 6.02, National Institute of Standards.</mixed-citation>
      </ref>
      <ref id="ref-r7">
        <mixed-citation publication-type="journal">Chen,J.C., 1966, &quot;A correlation for boiling heat transfer to saturated fluids in vertical flow&quot;, Heat Transfer Engineering, Vol.1, No.4, pp.32~37.</mixed-citation>
      </ref>
      <ref id="ref-r8">
        <mixed-citation publication-type="journal">Shah,M.M., 1982, &quot;Chart correlation for saturated boiling heattransfer equations and further study&quot;, ASHRAE Tran., Vol.88, pp. 185~196.</mixed-citation>
      </ref>
      <ref id="ref-r9">
        <mixed-citation publication-type="journal">Gungor, K.E. and Winterton, H.S., 1986, &quot;A general correlation for flow boiling in tubes and annuli&quot;, Int. J. Heat and Mass Transfer, Vol. 29, No. 3, pp. 351 ~ 358.</mixed-citation>
      </ref>
      <ref id="ref-r10">
        <mixed-citation publication-type="journal">Jung, D.S, McLinden, M., Randermacher, R and Didion, D., 1989, &quot;A study of flow boiling heat transfer with refrigerant mixtures&quot;, Int. J. Heat and Mass Transfer, Vol. 32, No. 9, pp. 1751 ~ 1764.</mixed-citation>
      </ref>
      <ref id="ref-r11">
        <mixed-citation publication-type="journal">Kandlikar, S.G., 1990, &quot;A general correlation for saturated two-phase flow boiling horizontal and vertical tubes&quot;, Trans. ASME, Vol. 112, pp. 219 ~ 228.</mixed-citation>
      </ref>
      <ref id="ref-r12">
        <mixed-citation publication-type="journal">Oh, H-K, Katsuta, M. and Shibata, K. 1998, &quot;Heat transfer characteristics of R-134a ina capillary tube heat exchanger&quot;, Proceedings of 11th IHTC. Vol. 6, pp. 131 ~ 136.</mixed-citation>
      </ref>
      <ref id="ref-r13">
        <mixed-citation publication-type="journal">Dittus, F.W., and Boelter, L.M.K.,1930, University of California, Berkeley, Publications on Engineering, Vol. 2, pp. 443.</mixed-citation>
      </ref>
      <ref id="ref-r14">
        <mixed-citation publication-type="journal">Lockhart, R.W. and Martnielli, R.C., 1945, &quot;Proposed correlation of data for isothermal two-phase, two-component flow in pipes&quot;, Chem. Eng., Prog., 45-1, pp. 39 ~ 48.</mixed-citation>
      </ref>
      <ref id="ref-r15">
        <mixed-citation publication-type="journal">Oh Hoo-Kyu, Park Ki-Won, Roh Geon-Sang, Hong Jin-Woo, Son Chang-Hyo, 2002, Evaporating heat transfer characteristics in small diameter tubes, Proceeding of Asian Conference on Refrigeration and Air Conditioning, Kobe, Japan, pp. 45 ~ 52.</mixed-citation>
      </ref>
    </ref-list>
  </back>