<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2005.116</article-id>
      <article-id pub-id-type="publisher-id">2005.116</article-id>
      <title-group><article-title>The Modelling of Ground-Coupled Heat Pump Systems</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Qu</surname><given-names>Yunxia</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Zhang</surname><given-names>Linhua</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Dong</surname><given-names>Rui</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">ShanDong University of Architecture and Engineering, Jinan, China</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>23</day><month>09</month><year>2005</year></pub-date>
      <volume>4</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-7-112-07718-2</isbn>
      <fpage>522</fpage>
      <lpage>525</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2005.116"/>
      <history>
        <date date-type="received"><string-date>23 September 2005</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2005 Copyright WSSET</copyright-statement>
        <copyright-year>2005</copyright-year>
      </permissions>
      <abstract><p>The research on ground-coupled heat pump systems mostly focuses on the modelling of geothermal heat exchanger and some experimental study on system performance. The transient model of geothermal heat exchangers with vertical ground-coupled buried tubes firstly is developed according to conservation of mass and energy in this paper. Then the system model is also established. It consists of two coupled models, one is antifreeze solution loop between the geothermal heat exchanger and a unit, and another is refrigerant loop in heat pump unit. The system performance, such as system cooling capacity, power input and so on, can be predicted according to this model in different layout of geothermal heat exchanger. The experimental result shows that the maximum error of performance factors between predicted and measured data does not exceed percent 10.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>ground-coupled heat pump systems</kwd>
        <kwd>geothermal heat exchanger</kwd>
        <kwd>model</kwd>
      </kwd-group>
      <conference>
        <conf-date>23 to 25 September 2005</conf-date>
        <conf-name>4th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2005</conf-acronym>
        <conf-num>4</conf-num>
        <conf-loc>Jinan, China</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">Kavaragh S. P. Ground source heat pump ASHRAE Journal, 40(10): 22-26, 1998. USA.</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">Bose J E, Parker J D, McQuiston F C. Design/data manual for closed-loop ground-coupled heat pump systems, Atlanta: ASHRAE.1985. USA.</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">Gu Y and O’Neal D L. Development of an equivalent diameter expression for vertical U-tube in ground-coupled heat pumps. ASHRAE Trans. 1998, 104(2): 347-355.</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">Hellstrom G. Ground heat storage, Thermal analysis of duct storage systems. Department of Mathematical Physics, University of Lund, Sweden, 1991.</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">Zeng H Y, Diao N R and Fang Z H, A finite line-source model for boreholes in geothermal heat exchangers, Heat Transfer – Asian Research, 31(7): 558-567, 2002.</mixed-citation>
      </ref>
      <ref id="ref-r6">
        <mixed-citation publication-type="journal">Heyi Zeng, Nairen Diao, Zhaohong Fang, Efficiency of vertical geothermal Heat Exchangers in the Ground Source heat pump system, The first international symposium on thermal science and engineering, beijing, 2002. CHINA.</mixed-citation>
      </ref>
      <ref id="ref-r7">
        <mixed-citation publication-type="journal">Nairen Diao, Ping Cui Zhaohong Fang, The thermal resistance in a borehole of geothermal heat exchangers, Proc. 12th International Heat Transfer Conference, 2002.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>
