<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2005.118</article-id>
      <article-id pub-id-type="publisher-id">2005.118</article-id>
      <title-group><article-title>Experimental Study on the Pressure Drop and Water Cooling Characteristics by Steam Driven Ejector and Jet Condenser</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Shin</surname><given-names>You Sik</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Lee</surname><given-names>Youn Hwan</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Jeong</surname><given-names>Hyo Min</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Chung</surname><given-names>Han Shik</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Chun</surname><given-names>Young Heung</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Kim</surname><given-names>Sun Jung</given-names></name>
        <xref ref-type="aff" rid="aff3"/>
      </contrib>
      <aff id="aff1">Graduate School, Dept. of Mechanical and Precision Engineering, Gyeongsang National University, Tongyeong, KOREA</aff>
      <aff id="aff2">School of Mechanical and Aerospace Engineering, Gyeongsang National University, Tongyeong, KOREA</aff>
      <aff id="aff3">Department of Building Services Engineering, Hanbat National University, Daejeon, KOREA</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>23</day><month>09</month><year>2005</year></pub-date>
      <volume>4</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-7-112-07718-2</isbn>
      <fpage>532</fpage>
      <lpage>537</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2005.118"/>
      <history>
        <date date-type="received"><string-date>23 September 2005</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2005 Copyright WSSET</copyright-statement>
        <copyright-year>2005</copyright-year>
      </permissions>
      <abstract><p>This study performed of a water cooling system by using a steam ejector and jet condenser to drop the temperature of the water in aquafarm by about 5°C from 25°C or higher. In this research, to replace the present water cooling system, we focused on a water cooling system operated by latent heat of evaporation, thus this system needs a vacuum pressure to evaporate the water in enclosed tank. The water cooling effects are dependent on the vacuum pressure in the enclosed tank, and the cooling water is generated by evaporation. As the experimental results, the absolute vacuum pressure obtained was about 5~8mmHg using a steam driven ejector with jet condenser in experiments from Type 1 to Type12. The temperature difference of the water is about 5°C from Figure 8, 10, 12. Figure 13, 15 and 17 is the graphs of temperature difference of heat exchanger. The obtained results are respectively ΔT=7°C, ΔT=5°C and ΔT=5.5°C. Figure 19, 21 and 23 is the graphs of temperature difference of heat exchanger. The obtained results are respectively ΔT=5.5°C, ΔT=5.5°C and ΔT=5.5°C.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>driven ejector</kwd>
        <kwd>Jet condenser</kwd>
        <kwd>Aquafarm</kwd>
        <kwd>Vacuum</kwd>
        <kwd>Latent heat of evaporation</kwd>
      </kwd-group>
      <conference>
        <conf-date>23 to 25 September 2005</conf-date>
        <conf-name>4th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2005</conf-acronym>
        <conf-num>4</conf-num>
        <conf-loc>Jinan, China</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">Jeong, H. M. and Chung, H. S. ,1998, Study on Fluid Flow Characteristics of Aquarium for Optimum Environment, Air-Conditioning and Refrigeration Engineering., 10, 1, pp108-117.</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">Tsutomu Takagi, Kausuaki Nashimoto, Katsutaro Yamamoto and Tomonori Hiraishi1993,Kang, W. J., Cho, S. S., Huh, H. and Chung, D. T.1998, Identificatoin of Dynamic Behavior of Sheet Metals for an Auto-body with Tension Split Hopkinson Bar, SAE 981010, pp115-119.</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">Kim, H. G. 1997. Recent Harmful Algal Blooms and Mitgatio Stategies in Korea. Ocean Research, Vol 19(2), pp185-192.</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">Lee, J. S. ,1994, Hydraulic Studies on Recirculating Aquaculture Basin, J. Korean Fish. Soc, 27, 2, pp173-182.</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">Sannomiya, N. and Matuda, K.,1987, Least Squares Estmation in Fish Behavior Model, Bull. Japan. Soc. Sci. Fish., 53, pp1951-1957.</mixed-citation>
      </ref>
      <ref id="ref-r6">
        <mixed-citation publication-type="journal">Partridge, B. L., 1989, The Structure ad Function of Fish School, Sci. Am., 246, pp90-99.</mixed-citation>
      </ref>
      <ref id="ref-r7">
        <mixed-citation publication-type="journal">Tomonori Hiraishi, Karsuaki Nashimoto, Thutomu Takagi, Kengo Suxuki and Keiichiro Moromatu, 1995, Stationary Ability of Bastard Halibut Paralichthys olivaceus and Longsnout Flounder Limanda punctatissima to Water Current at the Bottom of a Net Cage, Bulletin of the Japanese Society of Scientific Fisheries, 61, 3, pp363-368.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>