      <title-group><article-title>Recovery Waste Heat from Flue Gas of Natural Gas by Heat Pump</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Tian</surname><given-names>Guansan</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Li</surname><given-names>Xingquan</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">School of Thermal Energy Engineering, Shandong University of Architecture and Engineering</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>23</day><month>09</month><year>2005</year></pub-date>
      <volume>4</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-7-112-07718-2</isbn>
      <fpage>538</fpage>
      <lpage>542</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2005.119"/>
      <history>
        <date date-type="received"><string-date>23 September 2005</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2005 Copyright WSSET</copyright-statement>
        <copyright-year>2005</copyright-year>
      </permissions>
      <abstract><p>According the combustion theory, fist law of thermodynamics and gas law, analyses are made on the dew-point temperature, saturated humidity and enthalpy of flue gas of combusted natural gas. The calculating equations for these parameters are derived and the corresponding calculating results are given in patterns of curves, which can be used as the base for recovery waste heat from flue gas of natural gas. A new technical flow chart is put up what have a heat exchanger and three parallel heat pumps. Basing on it the actual COP of each heat pump can exceed 3 in winter. If the flue gas temperature is cooled down from 100°C~200°C to 40°C~30°C, the use of the sensible heat and latent heat of partial condensation of flue gas can be at a high level, and the thermal efficiency of natural gas can be raised 10%~20%.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>flue gas</kwd>
        <kwd>dew point</kwd>
        <kwd>condensation</kwd>
        <kwd>heat pump</kwd>
        <kwd>flow chart</kwd>
      </kwd-group>
      <conference>
        <conf-date>23 to 25 September 2005</conf-date>
        <conf-name>4th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2005</conf-acronym>
        <conf-num>4</conf-num>
        <conf-loc>Jinan, China</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">F. Haase, H. K0ehne, Design of Scrubbers for Condensing Boilers, Progress in Energy and Combustion Science 25, 1999, 305-337.</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">J. Kuck, EFFICIENCY OF VAPOUE-PUMP-EQUIPPED CONDENSING BOILERS, Applied Thermal Engineering, Vol.16. No.3 P233-244,1996.</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">F.A.lland, F.A. Watson and S. Devotta, Thermodynamic Design Data For Heat Pump Systems, oxford: Pergamon Press, 1982,p1-30.</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">Tongji University et al. Gas Combustion and Application. Beijing：China Architecture and Building Press，1988.1－17.</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">Akio Miyara, Shigeru Koyama: Consideration of the Performance of a Vapor-Compression Heat-pump Cycle Using Non-azeotropic refrigerant Mixtures, Int. J. Refrig.,Vol.15，No.1,1992.</mixed-citation>
      </ref>
      <ref id="ref-r6">
        <mixed-citation publication-type="journal">Tian Guan-san，Fu Lin，Jiang Yi，ANALYSIS AND ASSESSMENTS ON THE EXPLOSIVE HAZARDS OF LEAKAGE GAS FROM INDOORS GAS SYSTEM，The 4th International Symposium on HVAC Beijing, China, October 9-11, 2003.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>