<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2006.094</article-id>
      <article-id pub-id-type="publisher-id">2006.094</article-id>
      <title-group><article-title>Variable Speed Scroll Compressor’s Effective Energy Efficiency in Continuous Load Adjusting Chillers: a New Design Method</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>De Pascalis</surname><given-names>L.</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>pindepa@libero.it</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Starace</surname><given-names>G.</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>giuseppe.starace@unile.it</email>
      </contrib>
      <aff id="aff1">Department of Ingegneria dell’Innovazione, Università degli Studi di Lecce, via per Arnesano – 73100 Lecce, Italy</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>30</day><month>08</month><year>2006</year></pub-date>
      <volume>5</volume>
      <isbn publication-format="electronic">978-88-89884-05-8</isbn>
      <fpage>1</fpage>
      <lpage>6</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2006.094"/>
      <history>
        <date date-type="received"><string-date>30 August 2006</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2006 Copyright WSSET</copyright-statement>
        <copyright-year>2006</copyright-year>
      </permissions>
      <abstract><p>The new scroll driven chiller provided with an inverter for continuous load adjusting has been analyzed in order to investigate effective efficiency curves in all of the interesting working conditions, both at full and partial loads. Many analytical and experimental models propose efficiency calculation methods that sometimes result hard to be applied in the design process. So, a new simplified design method has been proposed, based on a global efficiency decrease range field, to reach optimal energy savings and to catch proper information about real chiller performance.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>scroll</kwd>
        <kwd>efficiency</kwd>
        <kwd>compression ratio</kwd>
        <kwd>drive frequency</kwd>
      </kwd-group>
      <conference>
        <conf-date>30 August to 1 September 2006</conf-date>
        <conf-name>5th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2006</conf-acronym>
        <conf-num>5</conf-num>
        <conf-loc>Vicenza, Italy</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>
