      <title-group><article-title>A Linear Fresnel concentrating Solar PVT System Design and Test in Korea</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Lee</surname><given-names>E J</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Kang</surname><given-names>E C</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">Korea Institute of Energy Research, Daejeon, Korea</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>24</day><month>08</month><year>2008</year></pub-date>
      <volume>7</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-1-995850-08-5</isbn>
      <fpage>297</fpage>
      <lpage>304</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2008.037"/>
      <history>
        <date date-type="received"><string-date>24 August 2008</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2008 Copyright WSSET</copyright-statement>
        <copyright-year>2008</copyright-year>
      </permissions>
      <abstract><p>A non-imaging linear Fresnel concentrating photovoltaic system with geometric concentration ratio of 5.7 is designed and tested at KIER in Daejeon, South Korea. The optical efficiency of the concentrator was 57% at an effective concentration ratio of 3.2. Only 57% of the concentrating light was illuminating the PV module, therefore, the optical efficiency and effective concentration ratio were lower than the expected values. Furthermore, the lateral distribution of the temperature suggested the non-uniformity of concentrating light possibly due to misalignment or variation in the contour of Fresnel lens along its length. Outdoor current and voltage measurements showed that efficiency reduced from 21.8% to 14.4% under the concentration and resulting higher operating temperatures. The electrical power output of the PV module under Fresnel lens with tracking the sun measured across a load resistance was approximately 4 times higher than the fixed PV module without the Fresnel lens on clear sky winter days in Daejeon, South Korea. The experiences gained from the experiments on the non-imaging linear Fresnel lens concentrator PV will be the first towards developing a large non-imaging linear Fresnel lens concentrating PV system to improve the concentrating PVT system performance in Korea.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>linear Fresnel</kwd>
        <kwd>photovoltaic thermal (PVT)</kwd>
        <kwd>concentrator</kwd>
        <kwd>concentration ratio</kwd>
        <kwd>sunlight</kwd>
      </kwd-group>
      <conference>
        <conf-date>24 to 27 August 2008</conf-date>
        <conf-name>7th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2008</conf-acronym>
        <conf-num>7</conf-num>
        <conf-loc>Seoul, Korea</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">Whitfield, G. R. et al., 1999, “The Development and Testing of Small Concentrating PV Systems” Solar Energy, 67(1-3), pp. 23–34.</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">Leutz, R., Suzuki, A., Akisawa, A., and Kashiwagi, T., 1999, “Design of a Non-imaging Fresnel Lens for Solar Concentrators”, Solar Energy, 65(6), pp. 379-387.</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">Leutz R, and Suzuki A., 2001, Non-imaging Fresnel Lenses Design and Performance of Solar Concentrators, Springer, Berlin, Germany.</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">O’Neill, J., McDanal, A.J., and Jaster, P.A., 2002, “Development of Terrestrial Concentrator Modules Using High-Efficiency Multi-Junction Solar Cells” 29th IEEE Photovoltaic Specialists Conference, New Orleans, LA.</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">Naveed, A.T., Kang, E.C., and Lee, E.J., 2005, “Performance Improvement Justification of a Concentrating Photovoltaic (CPV) System over a Non-Concentrating PV System”, J. Korean Solar Energy Society, 4(4), pp.141-153.</mixed-citation>
      </ref>
      <ref id="ref-r6">
        <mixed-citation publication-type="journal">Green, M. A., Emery, K., King, D. L., Igari, S., and Warta, W., 2005, “Solar Cell Efficiency Table (Ver 26)”, Prog. Photovolt: Res. Appl., 13(5), pp. 387-392.</mixed-citation>
      </ref>
      <ref id="ref-r7">
        <mixed-citation publication-type="journal">Radziemska, E., 2003, “The Effect of Temperature on the Power Drop in Crystalline Silicon Solar Cells”, Renewable Energy, 28(1), pp. 1-12.</mixed-citation>
      </ref>
      <ref id="ref-r8">
        <mixed-citation publication-type="journal">Royne, A., Dey, C. J., and Mills, D. R., 2005, “Cooling of Photovoltaic Cells Under Concentrated Illumination: A Critical Review”, Solar Energy Materials &amp; Solar Cells, 86(4), pp. 451–483.</mixed-citation>
      </ref>
      <ref id="ref-r9">
        <mixed-citation publication-type="journal">Sun, J., Israeli, T., Reddy, T. A., Scoles, K., Gordon, J. M., and Feuermann, D., 2005, “Modeling and Experimental Evaluation of Passive Heat Sinks for Miniature High-Flux Photovoltaic Concentrators”, J. Solar Energy Engineering, 127(1), pp. 138-145.</mixed-citation>
      </ref>
      <ref id="ref-r10">
        <mixed-citation publication-type="journal">McConnel, R., 2005, “Concentrator Photovoltaic Technologies Review and Market Prospects”, Refocus, 6(4), pp.35-39.</mixed-citation>
      </ref>
      <ref id="ref-r11">
        <mixed-citation publication-type="journal">Alonso-Gracia. et al., 2006, “Experimental Study of Mismatch and Shading Effects in the I–V Characteristic of a Photovoltaic Module”, Solar Energy Mater. Solar Cells, 90(3) pp. 329-340.</mixed-citation>
      </ref>
      <ref id="ref-r12">
        <mixed-citation publication-type="journal">Sala, G. et al., 2003, Test, Rating and Specification of PV concentrator components and systems, C-Rating Project NNE-1999-00588 (Final Report), http://www.iesdef.upm.es/ies/CRATING/final_report_part2.pdf.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>