<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2008.045</article-id>
      <article-id pub-id-type="publisher-id">2008.045</article-id>
      <title-group><article-title>Effect of Air Gap on the Performance of Building-Integrated Photovoltaics</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Gan</surname><given-names>Guohui</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>Guohui.gan@nottingham.ac.uk</email>
      </contrib>
      <aff id="aff1">School of the Built Environment, University of Nottingham University Park, Nottingham NG7 2RD, UK</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>24</day><month>08</month><year>2008</year></pub-date>
      <volume>7</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-1-995850-08-5</isbn>
      <fpage>357</fpage>
      <lpage>364</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2008.045"/>
      <history>
        <date date-type="received"><string-date>24 August 2008</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2008 Copyright WSSET</copyright-statement>
        <copyright-year>2008</copyright-year>
      </permissions>
      <abstract><p>The efficiency of photovoltaic (PV) devices is approximately inversely proportional to the cell temperature and air flow around PV modules installed over or beside a building envelope can facilitate ventilation cooling and so reduce the problem of module overheating. The effect of the size of air gap between PV modules and the building envelope on the PV performance in terms of cell temperature has been investigated numerically for a range of roof pitches and panel lengths under two different settings of solar radation,. It has been found that the mean and maximum PV temperatures decrease with the increase in pitch angle and air gap. The mean PV temepratutre also decreases with increasing panel length for air gaps greater than or equal to 0.1 m whereas the maximum PV temperature generally increases with panel length but decreases when the panel length increases from two modules to three modules and the air gap is between 0.1 m and 0.125 m. Without adequate air circulation, overheating of PV modules would occur and hot spots could form near the top of modules with potential cell temepratures over 80°C above air temperature. To reduce possible overheating requires a minimum air gap of between 0.11 m and 0.15 m for multiple module installation and 0.16 m for single module installation.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>photovoltaics</kwd>
        <kwd>air gap</kwd>
        <kwd>natural convection</kwd>
        <kwd>solar radiation</kwd>
        <kwd>overheating</kwd>
      </kwd-group>
      <conference>
        <conf-date>24 to 27 August 2008</conf-date>
        <conf-name>7th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2008</conf-acronym>
        <conf-num>7</conf-num>
        <conf-loc>Seoul, Korea</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">IT Power, 2004. “Going solar: A guide to install photovoltaic systems on social housing properties”, www.itpower.co.uk</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">Stapleton, G. and Milne, G., 2005. “Australia's guide to environmentally sustainable homes - 4.7 Photovoltaic systems”, www.yourhome.gov.au/technial/fs47.htm.</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">McCabe, J., Brooks, B. and Newmiller, J., 2006. “Ramification of installed NOCT values”, Solar 2006 Conference, Denver, Colorado, July 8-13.</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">Guiavarch, A. and Peuportier, B., 2006. “Photovoltaic collectors efficiency according to their integration in buildings”, Solar Energy, 80, 65–77.</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">Brinkworth, B. J. Marshall, R. H. and Ibarah, Z., 2000. “A validated model of naturally ventilated PV cladding”, Solar Energy, 69(1), 67–81.</mixed-citation>
      </ref>
      <ref id="ref-r6">
        <mixed-citation publication-type="journal">FLUENT, 2005, Fluent Inc. New Hampshire, USA.</mixed-citation>
      </ref>
      <ref id="ref-r7">
        <mixed-citation publication-type="journal">Yakhot, V., and Orzsag, S. A., 1986. &quot;Renormalization group analysis of turbulence: I. basic theory&quot;, J. Sci. Comp. 1:1-51.</mixed-citation>
      </ref>
      <ref id="ref-r8">
        <mixed-citation publication-type="journal">Carvalho, M.G, Farias, T., Fontes, P., 1991. &quot;Predicting radiative heat transfer in absorbing, emitting and scattering media using the discrete transfer method&quot;, Fundamentals of Radiation Heat Transfer, ASME FED, 160, 17-26.</mixed-citation>
      </ref>
      <ref id="ref-r9">
        <mixed-citation publication-type="journal">BP Solar 485, www.bpsolar.com.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>