      <title-group><article-title>Temperature Effect on the Power Drop in Building-Integrated Photovoltaic Module</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Kim</surname><given-names>H. I.</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>hikim@kier.re.kr</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Kang</surname><given-names>G. H.</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>ghkang@kier.re.kr</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Park</surname><given-names>K. E.</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>kepark@kier.re.kr</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Yu</surname><given-names>G. J.</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>y-gj@kier.re.kr</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Suh</surname><given-names>S. J.</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
        <email>energeti@inha.ac.kr</email>
      </contrib>
      <aff id="aff1">Korea Institute of Energy Research, Daejeon, Korea</aff>
      <aff id="aff2">Dept. of Architecture, Inha University, Incheon, Korea</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>24</day><month>08</month><year>2008</year></pub-date>
      <volume>7</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-1-995850-08-5</isbn>
      <fpage>384</fpage>
      <lpage>388</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2008.049"/>
      <history>
        <date date-type="received"><string-date>24 August 2008</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2008 Copyright WSSET</copyright-statement>
        <copyright-year>2008</copyright-year>
      </permissions>
      <abstract><p>The market for building-integrated photovoltaic (BIPV) system is growing rapidly because PV system offers considerable scope for energy demand offsets and reduction of greenhouse gas emissions. The mounting technique of sloped roof PV is that an air gap exists between the rear of the module and the roof, providing a cooling effect. On the other hand, the integration technique of sloped roof PV is that additional cost of building material can cut down but no air gap exists. Therefore cooling device need to reduce the heat build-up behind the PV module. The aim of this paper is performance analysis of building-integrated photovoltaic module according to temperature by computer simulation and experiment. The module temperature of no free ventilated PV system is higher than free ventilated PV system about 13.4℃. By the results on simulation, the reduction of electrical power loss is 9.57% into cold facade according to free ventilation. The annual averaged PR of BIPV system into free ventilated is about 73.1%.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>BIPV (Building-integrated photovoltaic)</kwd>
        <kwd>performance analysis</kwd>
      </kwd-group>
      <conference>
        <conf-date>24 to 27 August 2008</conf-date>
        <conf-name>7th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2008</conf-acronym>
        <conf-num>7</conf-num>
        <conf-loc>Seoul, Korea</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">J. J. Bloem 2008. Evaluation of PV-integrated building application in well-controlled outdoor test environment. Building and Environment. Vol 43. pp205-216.</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">Antonio Luque, Steven Hegedus. 2003. Handbook of photovoltaic science and engineering. John Wiley &amp; Sons Ltd.</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">German solar energy society. 2005. Planning and installing photovoltaic systems. James &amp; James. pp275.</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">G. Notton, C. Cristofari, M. Mattei, P. Poggi. 2005. Modelling of a double-glass photovoltaic module using finite differences. Applied thermal engineering, Vol 25. pp2854-2877.</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">W. De Soto, S. A. Klein, W. A. Beckman, 2006. Improvement and validation of a meodel for photovoltaic array performance. Solar Energy, Vol 80. pp78-88.</mixed-citation>