      <title-group><article-title>An Experimental Study for Performance Evaluation of the Box type Double Skin Façade System</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Yee</surname><given-names>Jurng Jae</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>jjyee@dau.ac.kr</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Choi</surname><given-names>Jin Hyuk</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>kalco@naver.com</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Kim</surname><given-names>Yong Kyung</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
        <email>yongs25@kolon.com</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Lee</surname><given-names>Sung Jin</given-names></name>
        <xref ref-type="aff" rid="aff3"/>
        <email>f-ink@kolon.com</email>
      </contrib>
      <aff id="aff1">Faculty of Architectural Design and Engineering, Dong-A University, Busan, Korea</aff>
      <aff id="aff2">Senior research, Construction Technology Research Institute, Kolon E&amp;C, Yongin-si, Korea</aff>
      <aff id="aff3">Construction Technology Research Institute, Kolon E&amp;C, Yongin-si, Korea</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>24</day><month>08</month><year>2008</year></pub-date>
      <volume>7</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-1-995850-08-5</isbn>
      <fpage>604</fpage>
      <lpage>611</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2008.076"/>
      <history>
        <date date-type="received"><string-date>24 August 2008</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2008 Copyright WSSET</copyright-statement>
        <copyright-year>2008</copyright-year>
      </permissions>
      <abstract><p>The purpose of this study is to evaluate the environmental performance of the box type double skin facade (DSF) system. The results of this study are as follows; (1) the peak of air temperature within the air cavity appeared 1 hour later after the peak time of outdoor temperature. It appears that the air cavity had a time delay effect. (2) There was about 3℃ temperature difference between the upper zone and the lower zone in case3. It appears that the sun control window films could reduce the solar radiation. (3) The difference of sound pressure level (SPL) between case1 and case4 was up to 32.4dB, at least 17.3dB in each frequency band. it appears that sound insulation effect of DSF system would be approximately 39dB (4) The difference of the illuminance level between separation distance, 1m, and separation distance 5m, was up to approximately 1350lx, at least approximately 250lx. It appears that it would not be necessary to use artificial lighting within 3m from window side because of the natural lighting being through the window and light shelf.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Box type Double Skin Façade (DSF) system</kwd>
        <kwd>Air Cavity</kwd>
        <kwd>Sound Insulation</kwd>
        <kwd>Light Shelf</kwd>
      </kwd-group>
      <conference>
        <conf-date>24 to 27 August 2008</conf-date>
        <conf-name>7th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2008</conf-acronym>
        <conf-num>7</conf-num>
        <conf-loc>Seoul, Korea</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">J.J. Yee, J.H Choi, Y.K Kim and S.J Lee. 2007. An Estimation of Thermal Environment of Box-type Double Skin System with Experiment. Proceedings of the KIAEBS 2007 Autumn Annual Conference. pp208-213. Korea.</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">J.W. Eom. 2002. Evaluation of the Thermal Environment and Ventilation Performance for the Double Skin Building. Master's thesis University of Seoul. Korea.</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">C.Y. Park, K.H. Lee, Y.S. Yoon and C.H. Choi. 2007. A Comparative Experimental Study on Thermal Performance of Box-type Double Skin and Curtain Wall in Cooling Period. Journal of the Korean Solar Energy Society. Vol 27. No 2. pp111-119. Korea.</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">J.W. Eom, J.K. Kim, J.H. Huh and S. Cho. 2001. An Experimental Study on the Thermal Environment of the Double Skin Building System. Proceeding of Conference in Architectural Institute of Korea. Vol 21. No 2. pp977-980. Korea.</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">ISO 140-5. Field measurements of airborne sound insulation of facade elements and facade. Korea.</mixed-citation>
      </ref>