<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2008.082</article-id>
      <article-id pub-id-type="publisher-id">2008.082</article-id>
      <title-group><article-title>Fabrication and testing of a Non-Glass Vacuum-Tube Collector for Solar Energy Utilization</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Chen</surname><given-names>K.</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>chen@me.utah.edu</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Oh</surname><given-names>S. J.</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
        <email>osj2588@cheju.ac.kr</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Hyun</surname><given-names>J. H.</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
        <email>junho214@hanmail.net</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Kim</surname><given-names>N. J.</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
        <email>jnkim@cheju.ac.kr</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Lee</surname><given-names>Y. J.</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
        <email>leeyj@cheju.ac.kr</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Chun</surname><given-names>W. G.</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
        <email>wgchun@cheju.ac.kr</email>
      </contrib>
      <aff id="aff1">Department of Mechanical Engineering, University of Utah, SLC, Utah, USA</aff>
      <aff id="aff2">Department of Nuclear &amp; Energy Engineering, Cheju National University, Cheju, Korea</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>24</day><month>08</month><year>2008</year></pub-date>
      <volume>7</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-1-995850-08-5</isbn>
      <fpage>647</fpage>
      <lpage>653</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2008.082"/>
      <history>
        <date date-type="received"><string-date>24 August 2008</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2008 Copyright WSSET</copyright-statement>
        <copyright-year>2008</copyright-year>
      </permissions>
      <abstract><p>An evacuated tubular solar collector was fabricated from acrylics for improved resistance to shattering. A plasmatron was employed to apply a thin gas-barrier coating to the surfaces of the plastic tube to prevent/alleviate gas infiltration. Experiments were conducted to investigate the effect of vacuum level on the performance of the non-glass vacuum-tube solar collector. A finned heat pipe was inserted in the evacuated tube for solar energy collection and heat transfer to a water tank. Time variations of temperatures on the heat pipe surface and in the water tank were recorded and analyzed for different degrees of vacuum in the collector. A comparison between the steady-state temperatures of the non-glass collector and a commercial glass vacuum-tube collector was made to assess the feasibility of the use of evacuated plastic tubes for solar energy collection.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>non-glass</kwd>
        <kwd>solar energy collection</kwd>
        <kwd>vacuum-tube collector</kwd>
        <kwd>ZnO coating</kwd>
      </kwd-group>
      <conference>
        <conf-date>24 to 27 August 2008</conf-date>
        <conf-name>7th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2008</conf-acronym>
        <conf-num>7</conf-num>
        <conf-loc>Seoul, Korea</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">Kharchenko, N.V., Shvachko, N.A., “Experimental investigation of evacuated solar-energy collectors for solar heating systems,” Applied Solar Energy, v 27, n 4, 1991, pp. 65-70</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">Estrada-Gascat, C. A., Alvarez-Garcia, G., Cabanillass, R. E., Nairt, P. K., “Theoretical efficiency of an all-glass tubular solar collector using a chemically deposited SnS-Cu,S absorber inside the inner tube,” J. Phys. D: Appl. Phys. v 25, 1992, pp. 1142-1147.</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">Perez, R., Seals, R., Anderson, J., Menicucci, D., &quot;Calculating solar radiation received by tubular collectors,&quot; Transactions of the ASME. Journal of Solar Energy Engineering, v 117, n 4, Nov. 1995, pp. 341-344.</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">Ismanzhanov, A., Klychev, S.I., Satkulov, T.T., “Operation comparison characteristics of tubular water-heating solar collectors,” Applied Solar Energy, v 36, n 3, 2000, pp. 20-22.</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">Lee, Bofeng, “The progress and prospect of middle/high temperature evacuated tubular solar collector,” Renewable Energy, v 24, n 3-4, November-December, 2001, WREC VI 2000 Proceedings Additional Papers, pp. 539-544.</mixed-citation>
      </ref>
      <ref id="ref-r6">
        <mixed-citation publication-type="journal">Kudish, A.I., Evseev, E.G., Walter, G., Priebe, T., “Coaxial tubular solar collector constructed from polymeric materials: An experimental and transient simulation study,” Energy Conversion and Management, v 44, n 16, Sept. 2003, pp. 2549-2566.</mixed-citation>
      </ref>
      <ref id="ref-r7">
        <mixed-citation publication-type="journal">Shah, L.J., Furbo, S., “Vertical evacuated tubular-collectors utilizing solar radiation from all directions,” Applied Energy, v 78, n 4, Aug. 2004, pp. 371-395.</mixed-citation>
      </ref>
      <ref id="ref-r8">
        <mixed-citation publication-type="journal">Morrison, G.L., Budihardjo, I., Behnia, M., “Measurement and simulation of flow rate in a water-in-glass evacuated tube solar water heater,” Solar Energy, v 78, n 2, Feb. 2005, pp. 257-267.</mixed-citation>
      </ref>
      <ref id="ref-r9">
        <mixed-citation publication-type="journal">Hyun, J. H., Oh, S. J., Kim, N., Chun, W., “Problems and hurdles in designing a non-glass solar vacuum tube collector,” 6th International Conference on Sustainable Energy Technologies, Santiago, Chile, Sept. 5 to 7, 2007.</mixed-citation>
      </ref>
      <ref id="ref-r10">
        <mixed-citation publication-type="journal">Incropera, F. P., DeWitt, D. P., Bergman, T. L., Lavine, A. S., Fundamentals of Heat and Mass Transfer, 6th ed., John Wiley &amp; Sons, New York, 2007, pp. 559 – 597.</mixed-citation>
      </ref>
      <ref id="ref-r11">
        <mixed-citation publication-type="journal">Na, W., Zou, P., “Experimental investigation on thermal properties of a steel-jacketed steam pipeline with vacuum insulation,” 6th International Conference on Enhanced Building Operations, Heating Technologies for Energy Efficiency v III-2-5, Shenzhen, China, Nov. 6 to 8, 2006.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>