<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2008.093</article-id>
      <article-id pub-id-type="publisher-id">2008.093</article-id>
      <title-group><article-title>Experimental determination of the temperature variation across the flow channel in a natural convection solar air heater</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Ong</surname><given-names>K. S.</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>Ong.Kok.Seng@eng.monash.edu.my</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Tan</surname><given-names>Kenny</given-names></name>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Tee</surname><given-names>W. N.</given-names></name>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Chandok</surname><given-names>S.</given-names></name>
      </contrib>
      <aff id="aff1">Monash University Sunway Campus, Jalan Lagoon Selatan, 46150 Bandar Sunway, Malaysia</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>24</day><month>08</month><year>2008</year></pub-date>
      <volume>7</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-1-995850-08-5</isbn>
      <fpage>723</fpage>
      <lpage>729</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2008.093"/>
      <history>
        <date date-type="received"><string-date>24 August 2008</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2008 Copyright WSSET</copyright-statement>
        <copyright-year>2008</copyright-year>
      </permissions>
      <abstract><p>An experimental investigation was conducted to measure the temperature variation across the flow channel and to determine the performance of a natural convection solar air heater at various tilt angles from 15, 30 and 45o. The results of the temperature profile across the air gap showed that heat transfer from the absorber plate to the air stream was mainly by convection. At a particular section, mean air temperature could be calculated from the arithmetic mean of the temperature profile across the air gap to within + 2°C. The axial air temperature distribution was non linear and did not increase much beyond 1 m of collector length. It tended to decrease towards the end of the collector. Overall glass, absorber plate and mean air temperatures over the entire length of the solar air heater could be determined by averaging the mean axial temperatures to within + 2°C. The heater performed better as inclination increased.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Solar air heater</kwd>
        <kwd>natural convection</kwd>
        <kwd>inclination effects</kwd>
        <kwd>temperature profile across air gap</kwd>
        <kwd>axial temperature distribution</kwd>
      </kwd-group>
      <conference>
        <conf-date>24 to 27 August 2008</conf-date>
        <conf-name>7th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2008</conf-acronym>
        <conf-num>7</conf-num>
        <conf-loc>Seoul, Korea</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">Burek, S. A. M. And Habeb, A. (2007). Air flow and thermal efficiency characteristics in solar chimneys and Trombe walls. Energy and Buildings, 39, 128-135.</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">Pica, A. La, Rodono, G. and Volpes, R. (1993). An experimental investigation on natural convection of air in a vertical channel. Int. J. Heat Mass Transfer, 36, 611-616.</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">Sakonidou, E. P., Karapantsios, T. D., Balouktsis, A. I. and Chassapis, D. (2008). Modeling of the optimum tilt of a solar chimney for maximum air flow. Solar Energy, 82, 80-94.</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">Das, S. K. And Chakraverty, A. (1990). Annual performance of integrated collector modules at a suitable tilt for air heating system. Energy Conversion Management, 30, 251-259.</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">Prasad, M. and Chandra, K. S. (1990). Optimum tilt of solar collector for maximum natural flow. Energy Conversion Management, 30, 369-379.</mixed-citation>
      </ref>
      <ref id="ref-r6">
        <mixed-citation publication-type="journal">Ong, K. S. (2005). Performance of a natural convection solar air heater. J. Energy, Heat and Mass Transfer, 27, 229-246.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>