<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2008.222</article-id>
      <article-id pub-id-type="publisher-id">2008.222</article-id>
      <title-group><article-title>Sustainable Water Recycling System Using Membrane and Advanced Oxidation Process in Complex</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Kim</surname><given-names>Joonkyu</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Song</surname><given-names>Insang</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Jong</surname><given-names>Jisun</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Lee</surname><given-names>Sangjoon</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Kim</surname><given-names>Pyoungsan</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Jeong</surname><given-names>Euna</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Lee</surname><given-names>Myounggeun</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Choung</surname><given-names>Younkyoo</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>choung@yonsei.ac.kr</email>
      </contrib>
      <aff id="aff1">Department of Civil &amp; Environmental Engineering, College of Engineering, Yonsei University, Seoul (120-749), KOREA</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>24</day><month>08</month><year>2008</year></pub-date>
      <volume>7</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-1-995850-08-5</isbn>
      <fpage>1593</fpage>
      <lpage>1600</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2008.222"/>
      <history>
        <date date-type="received"><string-date>24 August 2008</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2008 Copyright WSSET</copyright-statement>
        <copyright-year>2008</copyright-year>
      </permissions>
      <abstract><p>If wastewater can be reused, both the demand for water and the amount of wastewater can be reduced. Wastewater originating from all sources in residential homes other than the toilet is defined as graywater. In this study, graywater was treated through a microfiltration membrane and oxidation process, and the efficiency of the removal of color, turbidity, COD, suspended solids, E.coli, total coliform, Salmonella and Staphylococcus was studied. The treated graywater was reused for purposes other than drinking and bathing, such as fire fighting, water for plants, water for the toilet and car washing. The pH of the treated graywater was 7-7.7. The efficiency of the removal of each factor with the micro filtration membrane was as follows: color (98%), turbidity (99%), COD (99%), suspended solids (99%), E.coli, total coliform, Salmonella and Staphylococcus (30%). Following the membrane filtration process, the efficiency of the removal of each factor using the oxidation process was as follows: color (100%), turbidity (99%), COD (99%), suspended solids (99%), E.coli, total coliform, Salmonella and Staphylococcus (100%). The quantity and quality of the graywater was sufficient to establish a sustainable water circulation system for the reuse of residential graywater. The A2O-MF membrane-AOP system showed good treatment capacity. The A2O-MF membrane system could effectively remove COD, turbidity, color, and suspended solids, while AOP was effective for the removal of E.coli, total coliform, Salmonella and Staphylococcus.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>graywater</kwd>
        <kwd>A2O-MFmembrane</kwd>
        <kwd>advanced oxidation process</kwd>
        <kwd>residential complex</kwd>
      </kwd-group>
      <conference>
        <conf-date>24 to 27 August 2008</conf-date>
        <conf-name>7th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2008</conf-acronym>
        <conf-num>7</conf-num>
        <conf-loc>Seoul, Korea</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">A. Dixon, D. Butler and A. Fewkes. J.1999. Guidelines for graywater reuse: health issues. IWEM. Vol. 13. pp 322-326. USA</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">A.D. Wheatley and S. Surendran, in C. Maksimovich, D. Butler and F.A. Memon, eds., 2003. Advances in Water Supply Management, Balkema, The Netherlands. pp. 545-550.</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">A. Gross, O. Shmueli, Z. E. Raveh. 2007. Recycled vertical flow constructed wetland(RVFCW)-a novel method of recycling graywater for irrigation in small communities and households. Chemosphere. Vol. 66 No.5. pp 916-923. Israel</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">C. Diaper, A. Dixon, D. Butler, A. Fewkes, S.A. Parsons, T. Stephenson, M. Strathern and J. Strutt. 2001. Water Sci. Technol., 43(10). 83-90. USA</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">E. Friedler and N.I. Galil. 2003 On-site greywater reuse in multi-story buildings: Sustainable solution for water saving. Efficient 2003, 2nd Int. Conf. on Efficient Use and Management of Urban Water Supply, Tenerife, Canary Islands, Spain. IWA, AWWA and AEAS</mixed-citation>
      </ref>
      <ref id="ref-r6">
        <mixed-citation publication-type="journal">E. Friedler, M. Hadari. 2006. Economic feasibility of on-site greywater reuse in multi-storey buildings. Desalination. Vol. 190. pp 221-234. Israel</mixed-citation>
      </ref>
      <ref id="ref-r7">
        <mixed-citation publication-type="journal">Ensar Oguz, Bulent Keskinler. 2008. Removal of color and COD from synthetic textile wastewaters using O3, PAC, H2O2 and HCO3-. Journal of Hazardous Materials. Vol. 151. pp 753-760. Turkey</mixed-citation>
      </ref>
      <ref id="ref-r8">
        <mixed-citation publication-type="journal">Guy Ramon, Michal Green, Raphael Semiat, Carlos Doseretz. 2004. Low strength graywater characterization and treatment by direct membrane filtration. Desalination. Vol.170.pp241-250. Israel</mixed-citation>
      </ref>
      <ref id="ref-r9">
        <mixed-citation publication-type="journal">J.G. March, M. Gual, F. Orozco. 2004. Experiences on graywater re-use for toilet flushing in a hotel. Desalination. Vol. 164. pp 241-247. Spain</mixed-citation>
      </ref>
      <ref id="ref-r10">
        <mixed-citation publication-type="journal">J.L. Garland, L.H. Levine, N.C. Yorio, J.L.Adams and K.L.Cook. 2000. Graywater processing in recirculating hydroponic systems: Phytotoxicity, surfactant degradation, and bacterial dynamics. Water research. Vol 34. NO. 12. pp3075-3086. USA</mixed-citation>
      </ref>
      <ref id="ref-r11">
        <mixed-citation publication-type="journal">J.L. Garland, L.H. Levine, N.C. Yorio, M.E. Hummerick. 2004. Response of graywater recycling systems based on hydroponic plant growth to three classes of surfactants. Water research, Vol. 38: 1952-1962. USA</mixed-citation>
      </ref>
      <ref id="ref-r12">
        <mixed-citation publication-type="journal">L.D. Nghiem, N. Oschmann, A.I. Schafer. 2006. Fouling in greywater recycling by direct ultrafiltration. Desalination. Vol. 187. pp 283-290. Germany</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>