      <title-group><article-title>Application of geothermal heat pumps in renovated campus building of Korea</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Lim</surname><given-names>Jae-Han</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>limit0@cju.ac.kr</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Kim</surname><given-names>Kwang-Soo</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
        <email>70dori@cju.ac.kr</email>
      </contrib>
      <aff id="aff1">Department of Architectural Engineering, Cheong-Ju University, Cheong-Ju, Republic of Korea</aff>
      <aff id="aff2">Department of Facilities in University, Cheong-Ju University, Cheong-Ju, Republic of Korea</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>24</day><month>08</month><year>2008</year></pub-date>
      <volume>7</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-1-995850-08-5</isbn>
      <fpage>1612</fpage>
      <lpage>1619</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2008.224"/>
      <history>
        <date date-type="received"><string-date>24 August 2008</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2008 Copyright WSSET</copyright-statement>
        <copyright-year>2008</copyright-year>
      </permissions>
      <abstract><p>Recently, geothermal heat pumps (GHPs), which are normally known as ground source heat pumps (GSHPs), offer some advantages for heating and cooling of residential and commercial buildings due to the higher energy efficiency compared with conventional EHP system. In Korea, the renewable energy sources are forced to apply to the public buildings, which have over 3,000 m² of floor area according to the law. While GHPs may be more costly to install initially than regular heat pumps, they can also produce markedly lower energy bills. For this reason, GHPs are scrutinized as the heating and cooling alternatives in renovation of the campus buildings in Korea. In this study, we would like to investigate the application methods of GHPs for renovation of campus building, and to compare the energy costs of GHPs with that of conventional system. Also, the objective of this study is to present an operation status of GSHPs in renovated campus building as an example.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Geothermal heat pumps (GHPs)</kwd>
        <kwd>Campus building renovation</kwd>
        <kwd>Energy bills</kwd>
      </kwd-group>
      <conference>
        <conf-date>24 to 27 August 2008</conf-date>
        <conf-name>7th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2008</conf-acronym>
        <conf-num>7</conf-num>
        <conf-loc>Seoul, Korea</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">Yusuf Ali Kara, Bedri Yuksel, 2001. Evaluation of low temperature geothermal energy through the use of heat pump. Energy Conversion and Management. Vol 42. Pp773-781.</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">Burkhard Sanner, Constantine Karytsas, Dimitrios Mendrino, Ladislaus Rybach. Current status of ground source heat pumps and underground thermal energy storage in Europe. 2003. Geothermics. Vol 32. Pp579-588.</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">A. Hepbasli, O. Akdemir. Energy and Exergy analysis of a ground source (geothermal) heat pump system. 2004. Energy Conversion &amp; Management. Vol 45. pp.737-753.</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">Mustafa Inalli, Hikmet Esen. Experimental thermal performance evaluation of a horizontal ground-source heat pump system. 2004. Applied Thermal Engineering. Vol 24. pp.2219-2232.</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">Douglas Cane, Andrew Morrison, Christopher J. Ireland. Maintenance and service costs of commercial building ground-source heat pump systems. 1998. ASHRAE Transaction. Vol 104. Part 2.</mixed-citation>
      </ref>
      <ref id="ref-r6">
        <mixed-citation publication-type="journal">Hikmet Esen, Mustafa Inalli, Mehmet Esen. Technoeconomic appraisal of a ground source heat pump system for a heating season in eastern Turkey. Energy Conversion &amp; Management. Vol 47. pp.1281-1297.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>