<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2008.235</article-id>
      <article-id pub-id-type="publisher-id">2008.235</article-id>
      <title-group><article-title>Performance of revolving bent heat pipe heat pump system</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Gillott</surname><given-names>Mark</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author" corresp="yes">
        <name><surname>Jiang</surname><given-names>Liben</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>liben.jiang@nottingham.ac.uk</email>
      </contrib>
      <aff id="aff1">School of the Built Environment The University of Nottingham University Park, Nottingham, NG7 2RD, UK</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>24</day><month>08</month><year>2008</year></pub-date>
      <volume>7</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-1-995850-08-5</isbn>
      <fpage>1690</fpage>
      <lpage>1701</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2008.235"/>
      <history>
        <date date-type="received"><string-date>24 August 2008</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2008 Copyright WSSET</copyright-statement>
        <copyright-year>2008</copyright-year>
      </permissions>
      <abstract><p>This paper presents the study of the novel thermoelectric heat pipe heat pumping system. Bent heat pipes with sintered powder were applied and positioned oppositely as centrifugal forces worked. Extra normal fan blades were required to improve the fan performance. Tests of fan performance were carried out, followed by the thermal performance, within which eight pieces of thermoelectric devices were applied. The results showed that the system can handle airflow of up to 168.7 m³/hr with the revolving speed of 600 RPM, and maximum static pressure is up to 37 Pa. The system can supply the heat of up to 257.1 W with the coefficient of performance (COP) of up to 1.96.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>heat pipe</kwd>
        <kwd>thermoelectric device</kwd>
        <kwd>heat pump</kwd>
      </kwd-group>
      <conference>
        <conf-date>24 to 27 August 2008</conf-date>
        <conf-name>7th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2008</conf-acronym>
        <conf-num>7</conf-num>
        <conf-loc>Seoul, Korea</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">S. B. Riffat and M. C. Gillott. 2002. Performance of a novel mechanical ventilation heat recovery heat pump system. Applied Thermal Engineering, Volume 22, Issue 7, May 2002, Pages 839-845</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">D.A. MacIntyre. 1992. The control of house dust mites by ventilation: a pilot study. From Ventilation for energy efficiency and optimum indoor air quality, 13th AIVC conference, Nice, France. PP497-507</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">Mark Gillott, Liben Jiang, Rabah Boukhanouf, Zhe Li. Experimental Investigation of Revolving Heat Pipes for Enhanced Thermoelectric Heat Pumping. In Proceedings of 5th International Conference on Sustainable Energy Technologies (SET2006), Vicenza, Italy 30 August – 1 September 2006</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">Peterson, G. P., and Wu, D. 1993. A review of rotating and revolving heat pipes. Heat and Technology, 11 (1-2): 191-228</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">Matijevic, M.; Djuric, M.; Zarargo, Z.; and Novakovic, M., 1992. “Improving Heat Transfer with Pool Boiling by Covering of Heating Surface with Metallic Spheres,” Heat Trans. Eng., Vol. 13, pp. 49-57.</mixed-citation>
      </ref>
      <ref id="ref-r6">
        <mixed-citation publication-type="journal">Yimin Xuan, Yuping Hong and Qiang Li. (2004). Investigation on transient behaviours of flat plate heat pipes. Experimental Thermal and Fluid Science, Volume 28, Issues 2-3, January 2004, Pages 249-255</mixed-citation>
      </ref>
      <ref id="ref-r7">
        <mixed-citation publication-type="journal">Gillott, Mark. 2000. A novel mechanical ventilation heat recovery / heat pump system. PhD thesis, The University of Nottingham, UK</mixed-citation>
      </ref>
      <ref id="ref-r8">
        <mixed-citation publication-type="journal">BS 848: Part 1: Fans for general purposes, Methods of testing performance, British Standards Institute, London. UK, 1980.</mixed-citation>
      </ref>
      <ref id="ref-r9">
        <mixed-citation publication-type="journal">CIBSE. 2002. CIBSE student members’ data book: Guide A: Environmental design.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>