      <title-group><article-title>Experimental performance of a novel Liquid Desiccant Dehumidification System</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Elzaidabi</surname><given-names>A. A.</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>laxae1@nottingham.ac.uk</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Omer</surname><given-names>S. A.</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Ma</surname><given-names>Xiaoli</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Riffat</surname><given-names>S. B.</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">Institute of Sustainable Energy Technology, School of Built Environment, University of Nottingham, Nottingham, UK.</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>24</day><month>08</month><year>2008</year></pub-date>
      <volume>7</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-1-995850-08-5</isbn>
      <fpage>1765</fpage>
      <lpage>1772</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2008.245"/>
      <history>
        <date date-type="received"><string-date>24 August 2008</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2008 Copyright WSSET</copyright-statement>
        <copyright-year>2008</copyright-year>
      </permissions>
      <abstract><p>This paper presents results of experiments conducted to investigate the performance of an energy efficient, liquid desiccant dehumidification, cooling system. The system was designed to deliver conditioned air supply to buildings in highly humid climate conditions. The system could also be used to provide precondition air for commercial and industrial building, and so will help to save energy and cost by reducing compressor and/or chiller capacities in the ordinary cooling units. The system has an added value of improved indoor air quality and comfort by removing excessive humidity when used under humid climates, thus reducing the rate of mould growth and mildew that create “sick building syndrome”. The system evaluated in the study incorporates a desiccant dehumidifier, heat exchangers and an indirect evaporative cooling core. The desiccant is regenerated through heat energy produced using electrical power, but it could also be generated using recovered heat from the building, if available at the required temperature. A 4.85kW cooling capacity system has been fabricated and tested. The results show that the system is able to remove a considerable amount of moisture from the air at a thermal efficiency of 68.5%. A temperature difference of 7°C and relative humidity difference of 27.6 % between the ambient and the supply air have been achieved during the test.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Energy efficient</kwd>
        <kwd>liquid desiccant dehumidifier</kwd>
        <kwd>evaporative cooling</kwd>
      </kwd-group>
      <conference>
        <conf-date>24 to 27 August 2008</conf-date>
        <conf-name>7th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2008</conf-acronym>
        <conf-num>7</conf-num>
        <conf-loc>Seoul, Korea</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">Sheridan, J. C. and Mitchell, J.W. 1985. Sol. Energy 34(2) 187.</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">Matsuki, K. and Saito, Y. (1992) Desiccant Cool. Dehumidification 134.</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">Mavroudaki, P. Beggs, C.B. Sleigh, P.A. Halliday, S.P. 2002. Appl. Therm Eng. 22 - 1129.</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">Daou, K.; Wang, R.Z and Xia, Z.Z. 2006. Desiccant cooling air conditioning: a review, Renewable and Sustainable Energy Reviews 10 - 55–77.</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">Brandemuehl, M. J.; Katejanekarn, T.; Dehumidification Characteristics of Commercial Building Applications, ASHRAE, - ceae.colorado.edu.</mixed-citation>
      </ref>
      <ref id="ref-r6">
        <mixed-citation publication-type="journal">Al-Farayedhi, A Gandhidasan, A Antar, P M, Abdul Gaffar, M S. 2005. Experimental Study of an Aqueous Desiccant Mixture System: Air Dehumidification and Desiccant Regeneration Journal of Power and Energy Volume 219, (8).</mixed-citation>
      </ref>
      <ref id="ref-r7">
        <mixed-citation publication-type="journal">Renato, M.; Lazzarin and Francesco Castellotti. 2007. A new heat pump desiccant dehumidifier for supermarket application, Energy and Buildings, Volume 39, Issue 1, Pages 59-65.</mixed-citation>
      </ref>
      <ref id="ref-r8">
        <mixed-citation publication-type="journal">Waugaman, A.Kini, D.G. and Kettleborough, C.F. 1993. Review of desiccant cooling system, Journal of energy resources technology, Volume 115 Pages 1-8.</mixed-citation>
      </ref>
      <ref id="ref-r9">
        <mixed-citation publication-type="journal">Sanjeev, Jain and Bansal, P.K. 2007. Performance analysis of liquid desiccant dehumidification systems, International Journal of Refrigeration, Volume 30, Issue 5, Pages 861-872.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>