      <title-group><article-title>Study on the Nozzle Exit Position of an ejector in a Combined Cooling system</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Kong</surname><given-names>Tae Woo</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>teokong@hotmail.com</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Shen</surname><given-names>Shengqiang</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>zzbshen@dlut.edu.cn</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Yang</surname><given-names>Yong</given-names></name>
      </contrib>
      <aff id="aff1">Department of Power Engineering, Dalian University of Technology, Dalian 116024, China</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>24</day><month>08</month><year>2008</year></pub-date>
      <volume>7</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-1-995850-08-5</isbn>
      <fpage>2019</fpage>
      <lpage>2024</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2008.284"/>
      <history>
        <date date-type="received"><string-date>24 August 2008</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2008 Copyright WSSET</copyright-statement>
        <copyright-year>2008</copyright-year>
      </permissions>
      <abstract><p>In this study, 60 ejectors designed for CFD calculation. The purpose of this study is to investigate the use of CFD in prediction performance of an ejector used refrigeration applications. An ejector analyses often use coefficients derived from experimental data for a set operating conditions with limited functionality. But, this study is two dimensional calculation of ejector performance. The ejector was designed three kind of primary nozzle constructed with three different throat diameters, for the purpose of examining the influence of primary nozzle geometry of ejector performance. These nozzles had the same area ratio (throat to the exit plane) of 16 and included divergent angle of 10o.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>ejector</kwd>
        <kwd>CFD</kwd>
        <kwd>supersonic</kwd>
      </kwd-group>
      <conference>
        <conf-date>24 to 27 August 2008</conf-date>
        <conf-name>7th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2008</conf-acronym>
        <conf-num>7</conf-num>
        <conf-loc>Seoul, Korea</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">Kanjanapon Chunnanond, Satha Aphornratana, An Experimental investigation of a steam ejector refrigeration: the analysis of the pressure profile along the ejector, Applied Thermal Engineering 24 (2004) 311-322.</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">keenan H, Neumann EP, Lustwerk F. An investigation of ejector design by analysis and experiment. J. Appl. Mech, Trans, ASME 1950, 229-309.</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">Munday, John T, Bagster DF, A new ejector theory applied to steam jet refrigeration, Ind. Chen, Process Des. Del. 1977, 442-449.</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">Huang BJ, Jiang CB, Fu Fl, Ejector performance characteristics and design analysis of jet refrigeration system, ASME, Turbines and Power 1985, 792-802.</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">B.J. Huang, J.M. Chang, C.P. Wang, V.A.Petrenko, A 1-D analysis of ejector performance, Int J Refrigeration 22(1999) 354-364.</mixed-citation>
      </ref>
      <ref id="ref-r6">
        <mixed-citation publication-type="journal">S. Aphornratana, I.W. Eames, A small capacity steam-ejector refrigerator: experimental investigation of a system using ejector with movable primary nozzle, Int J Refrigeration 20 (5) 1997, 352-358.</mixed-citation>
      </ref>
      <ref id="ref-r7">
        <mixed-citation publication-type="journal">E. Rusly, Lu Aye, W.W.S. Charters, A. Ooi, CFD analysis of ejector in a combined ejector cooling system, Int J Refrigeration 28 2005, 1092-1101.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>