<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2008.320</article-id>
      <article-id pub-id-type="publisher-id">2008.320</article-id>
      <title-group><article-title>Preliminary Experiment on Daylighting Performance of Lightpipe under Different Sky Conditions</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Kong</surname><given-names>Hyo Joo</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>hjk09005@hanmail.net</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Kim</surname><given-names>Jeong Tai</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>jtkim@khu.ac.kr</email>
      </contrib>
      <aff id="aff1">Architectural Engineering, Kyung Hee University, Yongin-si, Korea</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>24</day><month>08</month><year>2008</year></pub-date>
      <volume>7</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-1-995850-08-5</isbn>
      <fpage>2262</fpage>
      <lpage>2265</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2008.320"/>
      <history>
        <date date-type="received"><string-date>24 August 2008</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2008 Copyright WSSET</copyright-statement>
        <copyright-year>2008</copyright-year>
      </permissions>
      <abstract><p>In order to ensure that daylight buildings will become the preferred option in this millennium, it is necessary to optimise energy savings by taking into account the integration of daylighting. Lightpipe systems are considered to save lighting energy and improve visual comfort. Accordingly, the purpose of this study is daylight performance of Lightpipe under overcast sky and clear sky. For the purpose, lightpipe system was designed as 650 diameter, with and aspect ratio of 2. Agilent data logger and photometric sensor were used. Lightfactor and illuminance were used to analyse daylight performance under different sky condition.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>lightpipe</kwd>
        <kwd>illuminance</kwd>
        <kwd>Lightfactor</kwd>
      </kwd-group>
      <conference>
        <conf-date>24 to 27 August 2008</conf-date>
        <conf-name>7th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2008</conf-acronym>
        <conf-num>7</conf-num>
        <conf-loc>Seoul, Korea</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">D. Jenkis, T. Munner, &quot;Modelling light-pipe performance - a natural daylighting solution&quot;, Building and Environment, Vol. 38, pp. 965-972, 2003</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">G. Oakley, S. B. Riffat and L. Shao, &quot;Daylighting Performance of Lightpipes&quot;, Solar Energy, Vol. 69, No. 2, pp. 89-98, 2000</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">IEA SHC Task 21, &quot;Daylighting in Buildings&quot;, ECBCS Annex 29, 2000.06</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">M. Paroncini, B. Calcagni, F. Corvaro, &quot;Monitoring of a light-pipe system&quot;, Solar Energy, Vol. 81 pp. 1180-1186, 2007</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">S. Szokolay, &quot;Enrivonmental Science Handbook for Architects and Buildings, pp. 91, 1979</mixed-citation>
      </ref>
      <ref id="ref-r6">
        <mixed-citation publication-type="journal">William M. C. Lam, Sunlighting as Formgiver for Architecture, Van Nostrand Reinhold, New York, 1986, pp. 146-156</mixed-citation>
      </ref>
      <ref id="ref-r7">
        <mixed-citation publication-type="journal">http://www.solarspot.it/it/</mixed-citation>
      </ref>
      <ref id="ref-r8">
        <mixed-citation publication-type="journal">http://www.whilkor.com/</mixed-citation>
      </ref>
      <ref id="ref-r9">
        <mixed-citation publication-type="journal">http://en.wikipedia.org/wiki/Light_tube</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>