      <title-group><article-title>Evaluation of energy consumption in a building with louver shading devices</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Palmero-Marrero</surname><given-names>Ana I.</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Oliveira</surname><given-names>Armando C.</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">Faculty of Engineering, University of Porto (New Energy Tec. Unit) Rua Dr. Roberto Frias, 4200-465 Porto, Portugal</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>31</day><month>08</month><year>2009</year></pub-date>
      <volume>8</volume>
      <isbn publication-format="electronic">978-3-9813246-1-7</isbn>
      <fpage>1</fpage>
      <lpage>6</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2009.055"/>
      <history>
        <date date-type="received"><string-date>31 August 2009</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2009 Copyright WSSET</copyright-statement>
        <copyright-year>2009</copyright-year>
      </permissions>
      <abstract><p>External louvers are increasingly used to provide solar protection for building glazed surfaces. In this work, a general study of the effect of louver shading devices applied to different façades of a building is carried out, for different locations (latitudes). Building energy requirements for a building in the cooling and heating seasons is quantified for different window and louver areas, under climatic conditions of Mexico (Mexico), Cairo (Egypt), Lisbon (Portugal), Madrid (Spain), London (UK) and Helsinki (Finland). Also, operative and indoor temperatures were calculated through simulations using TRNSYS software, whereas the model for the shading geometry study was solved with EES software. Both horizontal and vertical louver layouts were considered. The results show that the integration of louver shading devices in the building leads to indoor comfortable thermal conditions and may lead to significant energy savings, by comparison to a building without shading devices.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>solar louvers</kwd>
        <kwd>building simulation</kwd>
        <kwd>energy requirements</kwd>
        <kwd>EES</kwd>
        <kwd>TRNSYS</kwd>
      </kwd-group>
      <conference>
        <conf-date>31 August to 3 September 2009</conf-date>