<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2009.068</article-id>
      <article-id pub-id-type="publisher-id">2009.068</article-id>
      <title-group><article-title>Actual Proof Test of Energy Conservation in Central Heating/Cooling System Adapting Surfactant Drag Reduction</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Takeuchi</surname><given-names>Hiromi</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>h-takeuchi@aist.go.jp</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Kawaguchi</surname><given-names>Yasuo</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Tokuhara</surname><given-names>Keiji</given-names></name>
        <xref ref-type="aff" rid="aff3"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Fujiwara</surname><given-names>Yozo</given-names></name>
        <xref ref-type="aff" rid="aff4"/>
      </contrib>
      <aff id="aff1">Energy Technology Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), 16-1, Onogawa, Tsukuba, 305-8569, Japan</aff>
      <aff id="aff2">Department of Mechanical Engineering, Tokyo University of Science, Noda, Japan</aff>
      <aff id="aff3">Shunan Regional Industry Promotion Center, Shunan, Japan</aff>
      <aff id="aff4">Fujiwara Environmental Science Institute, Sapporo, Japan</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>31</day><month>08</month><year>2009</year></pub-date>
      <volume>8</volume>
      <isbn publication-format="electronic">978-3-9813246-1-7</isbn>
      <fpage>1</fpage>
      <lpage>4</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2009.068"/>
      <history>
        <date date-type="received"><string-date>31 August 2009</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2009 Copyright WSSET</copyright-statement>
        <copyright-year>2009</copyright-year>
      </permissions>
      <abstract><p>Energy conservation test in central heating/cooling system using surfactant drag reduction was performed using the building of the Sapporo City Hall. It equips a pump with 37kW rated output for some 32tons of circulating water. LSP-01A was used as a surfactant and its concentration set at 0.4-0.5%. Reduction of energy consumption in the pump was measured by 65% in winter heating and by 47% in summer cooling. 52,000kW of electricity may be saved annually. Around 900days has passed after injection of surfactant, the system works successfully without problems of efficiency and rust.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>surfactant</kwd>
        <kwd>drag reduction</kwd>
        <kwd>central heating/cooling system</kwd>
      </kwd-group>
      <conference>
        <conf-date>31 August to 3 September 2009</conf-date>
        <conf-name>8th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2009</conf-acronym>
        <conf-num>8</conf-num>
        <conf-loc>Aachen, Germany</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>