<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2009.070</article-id>
      <article-id pub-id-type="publisher-id">2009.070</article-id>
      <title-group><article-title>New evaporative cooling integrated pneumatic clear foil cushion constructions</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Xie</surname><given-names>Fei</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Omer</surname><given-names>S.</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Riffat</surname><given-names>S. B.</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">School of the Built Environment, University of Nottingham, UK</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>31</day><month>08</month><year>2009</year></pub-date>
      <volume>8</volume>
      <isbn publication-format="electronic">978-3-9813246-1-7</isbn>
      <fpage>1</fpage>
      <lpage>7</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2009.070"/>
      <history>
        <date date-type="received"><string-date>31 August 2009</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2009 Copyright WSSET</copyright-statement>
        <copyright-year>2009</copyright-year>
      </permissions>
      <abstract><p>Inflated clear foil cushions, known as ETFE foil cushions have been recently developed as an alternative to glass for large-scale public buildings with large glazed areas. However Building envelopes clad with such cushions, such as the famous Eden project in UK need a dynamic system to control overheating in summer. A flowing liquid cooling film constructed within a clear multi-layer is presented in this paper. This enables rapid cooling effects on the building envelope. The system is based on an evaporative cooling system and is integrated with the inflated cushion to provide desired cooling effect eco-friendly. The implications of the forms and configurations of clear foil cushion constructions with and without a liquid cooling film in the overheating control are evaluated in this paper. Data were collected from a set of experiments to ascertain the effects of the foil material on heat transfer between the membranes. A comparative study of impacts of the results demonstrated that the thermal behaviour of a membrane skin depends mainly on convection and radiation heat transfer at its surfaces. These initial experimental results met the predictions from the analytic model, and are valuable for this novel dynamic cooling system design.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>clear foil cushion</kwd>
        <kwd>pneumatic constructions</kwd>
        <kwd>overheating control</kwd>
        <kwd>liquid film</kwd>
        <kwd>evaporative cooling</kwd>
        <kwd>heat transfer</kwd>
      </kwd-group>
      <conference>
        <conf-date>31 August to 3 September 2009</conf-date>
        <conf-name>8th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2009</conf-acronym>
        <conf-num>8</conf-num>
        <conf-loc>Aachen, Germany</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">FOILTEC Group of Companies, 2008 and 2009. UK. Technical information; available online: http://www.foiltec.de/</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">Richard Nelson, 2009, Liquid solar technologies, available online: http://www.solaroof.org/wiki/SolaRoof/LiquidSolarTech</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">British Stands Institution, ISO 6946:2007, Building components and building elements: Thermal resistance and thermal transmittance -Calculation method, pp12-17</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">CIBSE, CIBSE Guide A2, Weather and solar data. 1986. London Charted Institution of Building Service Engineers: London, UK.</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">Brian Forster, Marijke Mollaert. 2004. The European Design Guide for Tensile Surface Structusres. Tensinet., pp8-16. UK.</mixed-citation>
      </ref>
      <ref id="ref-r6">
        <mixed-citation publication-type="journal">CIBSE Guide A, Environmental design, page Bros. (Norwich) Ltd., Norwich, UK, pp2:27-2:38, 1999</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>