      <title-group><article-title>Introduction of Heat Recovery Chiller Control and Water System Design</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Jia</surname><given-names>Jing</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>jjjia@trane.com</email>
      </contrib>
      <aff id="aff1">Trane China Distribution, Shanghai, PRC</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>24</day><month>08</month><year>2010</year></pub-date>
      <volume>9</volume>
      <isbn publication-format="electronic">978-1-995850-04-7</isbn>
      <fpage>1</fpage>
      <lpage>5</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2010.007"/>
      <history>
        <date date-type="received"><string-date>24 August 2010</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2010 Copyright WSSET</copyright-statement>
        <copyright-year>2010</copyright-year>
      </permissions>
      <abstract><p>The features and chiller control of heat recovery are discussed for better chiller efficiency and reliable operation. Three optimized water system designs are introduced for different heat recovery options: the Preferential Loading design is for more heat, the Sidestream design is to meet heating load exactly without extra heat rejection, the Cascade design is for high water temperature</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Energy</kwd>
        <kwd>Heat recovery</kwd>
        <kwd>Chiller control</kwd>
        <kwd>Water system design</kwd>
      </kwd-group>
      <conference>
        <conf-date>24 to 27 August 2010</conf-date>
        <conf-name>9th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2010</conf-acronym>
        <conf-num>9</conf-num>
        <conf-loc>Shanghai, China</conf-loc>
      </conference>