<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2010.022</article-id>
      <article-id pub-id-type="publisher-id">2010.022</article-id>
      <title-group><article-title>A Study on performance of heat pump using domestic supply water source and geothermal source</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author" corresp="yes">
        <name><surname>Lee</surname><given-names>Byoungdoo</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Lee</surname><given-names>Sejin</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Lee</surname><given-names>Daewoo</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">Institute of Technology &amp; Quality Development, Hyundai Engineering &amp; Construction Co., Ltd, Seoul, Republic of Korea</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>24</day><month>08</month><year>2010</year></pub-date>
      <volume>9</volume>
      <isbn publication-format="electronic">978-1-995850-04-7</isbn>
      <fpage>1</fpage>
      <lpage>5</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2010.022"/>
      <history>
        <date date-type="received"><string-date>24 August 2010</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2010 Copyright WSSET</copyright-statement>
        <copyright-year>2010</copyright-year>
      </permissions>
      <abstract><p>This paper is to make it possible to check geothermal heat-pump performance by using building running water heat-source, a energy we never make use of. To check heat-pump performance, geothermal heat-pump 3RT, heat exchanger 100 m (￠12mm of PE) in water tank, and Vertical heat exchanger 100m (￠32mm of HDPE) were set up in Mock-up House. In fact, heatpump 3RT needs vertical heat exchanger 150m. The experimental results are that in winter season around 0.67RT was taken off from water tank and the rest 2.23 RT was from vertical heat exchanger while using domestic water (710 liter/day, based on 4 people) from water tank During the time of checking, geothermal heat-pump COP was at 4.2, which is enough to meet the standard of national geothermal heat-pump COP, 3.45. It depends on the amount of water supply, but It can be reduced to about 50m of vertical heat exchanger in Residential building so that you can save 20% of the total construction cost. In the future, the study on how to make optimal design in accordance with heat exchanger quality and shape in water tank.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Geothermal Heat Pump</kwd>
        <kwd>Water Storage Tank</kwd>
        <kwd>Borehole Heat Exchanger</kwd>
        <kwd>Municipal Waste Water</kwd>
      </kwd-group>
      <conference>
        <conf-date>24 to 27 August 2010</conf-date>
        <conf-name>9th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2010</conf-acronym>
        <conf-num>9</conf-num>
        <conf-loc>Shanghai, China</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>