<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2010.107</article-id>
      <article-id pub-id-type="publisher-id">2010.107</article-id>
      <title-group><article-title>Temperature reduction in attic and ceiling via insulation of several passive roof designs</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Ong</surname><given-names>K. S.</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>Ong.Kok.Seng@eng.monash.edu.my</email>
      </contrib>
      <aff id="aff1">Monash University Sunway Campus, Jalan Lagoon Selatan, 46150 Bandar Sunway, Malaysia</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>24</day><month>08</month><year>2010</year></pub-date>
      <volume>9</volume>
      <isbn publication-format="electronic">978-1-995850-04-7</isbn>
      <fpage>1</fpage>
      <lpage>8</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2010.107"/>
      <history>
        <date date-type="received"><string-date>24 August 2010</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2010 Copyright WSSET</copyright-statement>
        <copyright-year>2010</copyright-year>
      </permissions>
      <abstract><p>High ambient temperatures coupled with high humidity lead to uncomfortable conditions that are non-conducive for human comfort and productivity. Heat transmission through the roof could be reduced by providing insulation in the attic under the roof or above the ceiling. A roof solar collector could provide both ventilation and cooling in the attic. Several laboratory sized units of passive roof designs were constructed and tested side-by-side under outdoor conditions to obtain temperature data of the roof, attic and ceiling in order to compare their performances.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>solar energy</kwd>
        <kwd>passive roof designs</kwd>
        <kwd>insulation</kwd>
        <kwd>attic temperature</kwd>
        <kwd>ceiling temperature</kwd>
      </kwd-group>
      <conference>
        <conf-date>24 to 27 August 2010</conf-date>
        <conf-name>9th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2010</conf-acronym>
        <conf-num>9</conf-num>
        <conf-loc>Shanghai, China</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">Hall, J. A., Performance testing of radiant barriers (RB) with R11, R19 and R30 cellulose and rock wool insulation, ASHRAE Transaction, 73, (1988) 174-185.</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">Medina, M. A., On the performance of radiant heat barriers in combination with different attic insulation levels, Energy and Buildings, 33 (2000) 31-40.</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">Winiarski, D. W., and O’Neal, D. L., A quasi-steady-state model of attic heat transfer with radiant barriers, Energy and Buildings, 24 (1996) 183-194.</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">Soubdhan, T., Feuillard, T., and Bade, F., Experimental evaluation of insulation material in roofing system under tropical climate, Solar Energy, 79 (2005) 311-320.</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">Amer, E. H., Passive options for solar cooling of buildings in aid areas, Energy, 31 (2006) 1332-1344.</mixed-citation>
      </ref>
      <ref id="ref-r6">
        <mixed-citation publication-type="journal">Suehrcke, H., Peterson, E. L., and Selby, N., Effect of roof solar reflectance on the building heat gain in a hot climate, Energy and Buildings, 40 (2008) 2224-2235.</mixed-citation>
      </ref>
      <ref id="ref-r7">
        <mixed-citation publication-type="journal">Khedari, J., Mansirisub, W., Chaima, S., Pratinthong, N., and Hirunlabh, J., Field measurement of performance of roof solar collector, Energy and Buildings, 31 (2000) 171-178.</mixed-citation>
      </ref>
      <ref id="ref-r8">
        <mixed-citation publication-type="journal">Hirunlabh, J., Wachirapuwadon, S., Pratinthong, N., and Khedari, J., New configurations of a roof solar collector maximizing natural ventilation, Building and environment, 36, (2001) 383-391.</mixed-citation>
      </ref>
      <ref id="ref-r9">
        <mixed-citation publication-type="journal">Ong, K. S., Experimental investigations into solar-induced passive cooling with Trombe wall and roof solar collector. Proceedings ISES 2007, China, 2007, pp. 415-419.</mixed-citation>
      </ref>
      <ref id="ref-r10">
        <mixed-citation publication-type="journal">Mathews, E. H., Kleingeld, M., and Taylor, P. B., Estimating the electricity savings effect of ceiling insulation, Building and Environment, 34 (1999) 505-514.</mixed-citation>
      </ref>
      <ref id="ref-r11">
        <mixed-citation publication-type="journal">Taylor, P. B., Mathews, E. H., Kleingeld, M., and Taljaard, G. W., The effect of ceiling insulation on indoor comfort, Building and Environment, 35 (2000) 339-346.</mixed-citation>
      </ref>
      <ref id="ref-r12">
        <mixed-citation publication-type="journal">Al-Sallal, K. A., Comparison between polystyrene and fibreglass roof insulation in warm and cold climates, Renewable Energy, 28 (2003) 603-611.</mixed-citation>
      </ref>
      <ref id="ref-r13">
        <mixed-citation publication-type="journal">Ciampi, M., Leccese, F., and Tuoni, G., Energy analysis of ventilated and microvented roofs, Solar Energy (2005) 79, 183-192.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>