<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2010.149</article-id>
      <article-id pub-id-type="publisher-id">2010.149</article-id>
      <title-group><article-title>Experimental Performance of a Low-Concentrating Solar Photovoltaic /Thermal Integrated Heat Pump System</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Xu</surname><given-names>Guoying</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Zhang</surname><given-names>Xiaosong</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">School of Energy and Environment, Southeast University, Nanjing, China</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>24</day><month>08</month><year>2010</year></pub-date>
      <volume>9</volume>
      <isbn publication-format="electronic">978-1-995850-04-7</isbn>
      <fpage>1</fpage>
      <lpage>7</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2010.149"/>
      <history>
        <date date-type="received"><string-date>24 August 2010</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2010 Copyright WSSET</copyright-statement>
        <copyright-year>2010</copyright-year>
      </permissions>
      <abstract><p>A new type of low-concentrating solar photovoltaic/thermal integrated heat pump system (LCPV/T-HP) for generating electricity and heating residential water was developed. The solar photovoltaic/thermal collector with immovable parabolic reflectors concentrating the incident solar radiation into the photovoltaic modules, also acts as the evaporator of a heat pump. Refrigerant, R134a, absorbs the solar heat and evaporates inside the flow channels attached on the back of the photovoltaic modules, and then gets through a heat pump cycle to release heat to water in the condenser. The prototype was experimented in Nanjing, China. Results showed that LCPV/T-HP performed with high electrical and thermal efficiencies. The electricity generated by the LCPV/T-HP was 2.5 times that of the conventional non-concentrating PV system with the same areas of PV cells. Furthermore, the averaged coefficient of performance (COP) of the heat pump for heating water up to 50°C was 5.02 on a sunny day when the averaged ambient air temperature was 27 °C.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>solar photovoltaic/thermal</kwd>
        <kwd>heat pump</kwd>
        <kwd>solar concentrator</kwd>
        <kwd>electrical conversion efficiency</kwd>
      </kwd-group>
      <conference>
        <conf-date>24 to 27 August 2010</conf-date>
        <conf-name>9th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2010</conf-acronym>
        <conf-num>9</conf-num>
        <conf-loc>Shanghai, China</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">Huang, B.J., Lin, T.H., Hung, W.C., et al. 2001. Performance evaluation of solar photovoltaic /thermal systems. Solar Energy. Vol 70. No 5. pp443-448.</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">Zondag, H.A, Vries, D.W., Helden, W.G.J., et al. 2003. The yield of different combined PV/Thermal collector designs. Solar Energy. Vol 74, pp253-269.</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">Ji, J., Chow, T.T., He, W. 2003. Dynamic performance of hybrid photovoltaic/thermal collector wall in Hong Kong. Building and Environment. Vol 38. pp1327-1334.</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">Thomas, H. P., Hayter, S. J., Martin R. L., et al. 2000. PV and PV/hybrid products for buildings. Proceedings of the 16th European Photovoltaic Solar Energy Conference. Glasgow, UK.</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">Ito, S., Miura, N. 1997. Heat pump using a solar collector with photovoltaic modules on the surface. Journal of Solar Energy Engineering. Vol 119. pp147-151.</mixed-citation>
      </ref>
      <ref id="ref-r6">
        <mixed-citation publication-type="journal">Ji, J., Pei, G., Chow, T.T., et al. 2008. Experimental study of photovoltaic solar assisted heat pump system. Solar energy. Vol 82. pp43-52.</mixed-citation>
      </ref>
      <ref id="ref-r7">
        <mixed-citation publication-type="journal">Xu G.Y., Deng S.M., Zhang X.S., et al. 2009. Simulation of a photovoltaic /thermal heat pump system having a modified collector /evaporator. Solar Energy. Vol 83. pp1967-1976.</mixed-citation>
      </ref>
      <ref id="ref-r8">
        <mixed-citation publication-type="journal">Xu G.Y., Xu X.J., Zhang X.S., et al. 2007. Development and performance analysis on a photovoltaic-thermal integrated heat pump water heating system. Proceedings of ISES Solar World Congress. August. China.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>
