<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2011.006</article-id>
      <article-id pub-id-type="publisher-id">2011.006</article-id>
      <title-group><article-title>Natural Convection Counter-Flow Solar Air Heater</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author" corresp="yes">
        <name><surname>Bamgbopa</surname><given-names>M. O.</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <xref ref-type="aff" rid="aff2"/>
        <email>musbaudeen.bamgbopa@metu.edu.tr</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>AL-Khawaja</surname><given-names>M. F.</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Atikol</surname><given-names>U.</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
      </contrib>
      <aff id="aff1">Middle East Technical University Northern Cyprus Campus, TRNC via Mersin 10, Turkey</aff>
      <aff id="aff2">Department of Mechanical Engineering, Eastern Mediterranean University, Gazimagusa, TRNC via Mersin 10, Turkey</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>04</day><month>09</month><year>2011</year></pub-date>
      <volume>10</volume>
      <isbn publication-format="electronic">978-1-995850-03-0</isbn>
      <fpage>1</fpage>
      <lpage>6</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2011.006"/>
      <history>
        <date date-type="received"><string-date>4 September 2011</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2011 Copyright WSSET</copyright-statement>
        <copyright-year>2011</copyright-year>
      </permissions>
      <abstract><p>In this study, a natural convection counter flow solar air heater (SAH) was designed and investigated experimentally. The SAH has dimensions; 1.5 m lenght and 1 m width, with wire mesh as absorber. The idea of this novel design in pasive solar air heaters is to minimize heat losses from the front cover of the collector and to maximize heat extraction from the absorber. This was done by directing air to flow between two glazing covers (preheating the air) before returning to pass through the absorber, establishing a counter-flow sitaution in the natural convection SAH. Performance testing of the solar air heater on different clear days in Famagusta, North Cyprus shows that its efficiency increases with increasing mass flow rate for the obtained flow range of 0.0012 to 0.005kg/s. The maximum efficiency of operation obtained was approximately 17% at about 0.005kg/s, also maximum air temperature increase was 46°C at a solar radiation flux of about 950W/m².</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Solar Air heater</kwd>
        <kwd>Natural convection</kwd>
        <kwd>Counter-flow</kwd>
      </kwd-group>
      <conference>
        <conf-date>4 to 7 September 2011</conf-date>
        <conf-name>10th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2011</conf-acronym>
        <conf-num>10</conf-num>
        <conf-loc>Istanbul, Türkiye</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>