<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2011.037</article-id>
      <article-id pub-id-type="publisher-id">2011.037</article-id>
      <title-group><article-title>New Concepts and Approach for Developing Energy Efficient Buildings: Optimized Combined-Ventilation</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Cheng</surname><given-names>Rui</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author" corresp="yes">
        <name><surname>Zhang</surname><given-names>Yinping</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>zhangyp@mail.tsinghua.edu.cn</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Wang</surname><given-names>Xin</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">Department of Building Science, Tsinghua University, Beijing 100084, China</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>04</day><month>09</month><year>2011</year></pub-date>
      <volume>10</volume>
      <isbn publication-format="electronic">978-1-995850-03-0</isbn>
      <fpage>1</fpage>
      <lpage>7</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2011.037"/>
      <history>
        <date date-type="received"><string-date>4 September 2011</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2011 Copyright WSSET</copyright-statement>
        <copyright-year>2011</copyright-year>
      </permissions>
      <abstract><p>Mechanical ventilation combining with free cooling or air-conditioning (defined as combined-ventilation) in summer and transient seasons can effectively decrease the energy consumption of air conditioning systems for buildings. It’s difficult or even impossible to optimize the combined-ventilation rate by using traditional method, direct simulation method. Due to this, some new concepts—optimization of combined ventilation strategy based on an inverse problem to determine the optimized combined-ventilation rate was proposed by us. They can be used to optimize the mechanical ventilation rate so that the total energy consumption of the air-conditioning system in the building can be minimized. A two-plate model was adapted to simplify the thermal performance analysis of a real room, which was validated with the simulated results of DeST-a software widely-used building thermal performance in China. A kind of nonlinear optimized method, the Sequential Quadratic Programming (SQP) algorithm, was applied to solve this nonlinear problem. For illustrative purpose, the instantaneous combined-ventilation rate of a room in a building in Beijing in summer was optimized and a sensitivity analysis was conducted. It concludes that from the example: (1) The energy consumption can be decreased by 52.04% by optimization-the peak cooling demand can be decreased 45.89 % and the operative hours of an air-conditioning device can be reduced nearly 10 hours; (2) Optimized ventilation rate strongly depends on the temperature difference of mean walls’ surface and outdoor temperatures-a correlation between these two variables has been derived to determine the optimized combined-ventilation rate; (3) The energy saving potential for a building in a given climate area depends upon the so-called Effective Energy Efficiency Index. Based on the analysis, several suggestions are presented.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Ventilation</kwd>
        <kwd>energy efficient buildings</kwd>
        <kwd>inverse problem</kwd>
        <kwd>air-conditioning</kwd>
      </kwd-group>
      <conference>
        <conf-date>4 to 7 September 2011</conf-date>
        <conf-name>10th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2011</conf-acronym>
        <conf-num>10</conf-num>
        <conf-loc>Istanbul, Türkiye</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>