<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2012.036</article-id>
      <article-id pub-id-type="publisher-id">2012.036</article-id>
      <title-group><article-title>Ventilation and Architectural Design Strategies for Cooling Office Buildings in Different Climates of Chile</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Bustamante Gómez</surname><given-names>Waldo</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Encinas Pino</surname><given-names>Felipe</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Vera Araya</surname><given-names>Sergio</given-names></name>
        <xref ref-type="aff" rid="aff3"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Sánchez de la Flor</surname><given-names>Francisco</given-names></name>
        <xref ref-type="aff" rid="aff4"/>
      </contrib>
      <aff id="aff1">Escuela de Arquitectura. Pontificia Universidad Católica de Chile. Av. El Comendador 1916, Providencia, Santiago, Chile</aff>
      <aff id="aff2">Architecture et Climat. Université catholique de Louvain. Place du Levant 1. 1348 Louvain la Neuve, Belgium</aff>
      <aff id="aff3">Department of Construction Engineering and Management. Escuela de Ingeniería, Pontificia Universidad Católica de Chile Av. Vicuña Mackenna 4860. Macul, Santiago, Chile</aff>
      <aff id="aff4">Escuela Superior de Ingeniería de Cádiz. Calle Chile 1. Cádiz, España</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>02</day><month>09</month><year>2012</year></pub-date>
      <volume>11</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-1-995850-02-3</isbn>
      <fpage>356</fpage>
      <lpage>363</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2012.036"/>
      <history>
        <date date-type="received"><string-date>2 September 2012</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2012 Copyright WSSET</copyright-statement>
        <copyright-year>2012</copyright-year>
      </permissions>
      <abstract><p>Office buildings in Chile show higher cooling than heating energy demand. The climate of the country show important differences between cities by the ocean and those of interior regions. Main cities of Central Chile are Santiago and Valparaíso, both located at around 33° S. Santiago presents a Mediterranean climate, with a high temperature oscillation between day and night during cooling period. Valparaíso, by the coast, shows lower temperature fluctuation compared with Santiago during identical period. In order to define design strategies for energy efficiency of office buildings in mentioned cities, a sensitivity study has been made, considering variables like window to wall ratio, type of windows (clear and selective glazing, including low e, single and double glazing), use and type of external solar protection (ESP) and use of nocturnal or diurnal ventilation. In opaque facades, thermal insulation is considered. In case of walls, in order to increase thermal inertia external insulation is assumed. The sensitivity analysis is developed considering a square building containing office rooms on all four orientations. This10 story building has been specially proposed and designed for this analysis. Methodology considers an evaluation of heating and cooling demand of the building in both cities. For this purpose, a simulation software under dynamic conditions has been used (TAS). The lowest cooling energy demand is reached when using the lowest window to wall ratio (20%), with ESP in east, west and north oriented glazed areas. In fact, fully glazed facades in both cities are not recommended. Nocturnal ventilation was highly effective for decreasing cooling demand in both cities. In the case of Valparaíso, due to relatively low temperature during cooling period (maximum lower than 26°C), diurnal ventilation for cooling purposes is also effective.</p></abstract>
      <conference>
        <conf-date>2 to 5 September 2012</conf-date>
        <conf-name>11th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2012</conf-acronym>
        <conf-num>11</conf-num>
        <conf-loc>Vancouver, Canada</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>
