<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2012.111</article-id>
      <article-id pub-id-type="publisher-id">2012.111</article-id>
      <title-group><article-title>Experimental Investigation on an Ejector Cooling System</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Chen</surname><given-names>Xiangjie</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Worall</surname><given-names>Mark</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Riffat</surname><given-names>Saffa</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">Department of Built Environment, University of Nottingham, Nottingham, Ng7 2RD, United Kingdom</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>02</day><month>09</month><year>2012</year></pub-date>
      <volume>11</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-1-995850-02-3</isbn>
      <fpage>1083</fpage>
      <lpage>1093</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2012.111"/>
      <history>
        <date date-type="received"><string-date>2 September 2012</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2012 Copyright WSSET</copyright-statement>
        <copyright-year>2012</copyright-year>
      </permissions>
      <abstract><p>In order to analysis the feasibility and efficiency of a small scale steam ejector cooling system, a 0.5kW cooling capacity steam ejector system was constructed and tested under boiler temperature in the range 115°C to 130°C, and evaporator temperature in the range of 5°C to 10°C. System performances under different operating conditions including various boiler temperatures, evaporator temperatures and condenser pressures, were tested and reported. The effects of nozzle exit position on ejector performance were analyzed. Performance maps, useful for design and application were also presented. The results of both theoretical simulation and experimental study were compared and analyzed. The experimental data were found to be around 85% of the theoretical values.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Ejector</kwd>
        <kwd>cooling</kwd>
        <kwd>water</kwd>
        <kwd>experimental investigation</kwd>
      </kwd-group>
      <conference>
        <conf-date>2 to 5 September 2012</conf-date>
        <conf-name>11th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2012</conf-acronym>
        <conf-num>11</conf-num>
        <conf-loc>Vancouver, Canada</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>
