<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2012.211</article-id>
      <article-id pub-id-type="publisher-id">2012.211</article-id>
      <title-group><article-title>Environmentally Friendly Systems: Earth Heat Pump System with Vertical Pipes for Heat Extraction for Domestic Heating and Cooling</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Omer</surname><given-names>Abdeen</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Omer</surname><given-names>Siddig</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Riffat</surname><given-names>Saffa</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">School of the Built Environment, University of Nottingham NG7 2RD, UK</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>02</day><month>09</month><year>2012</year></pub-date>
      <volume>11</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-1-995850-02-3</isbn>
      <fpage>1976</fpage>
      <lpage>1986</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2012.211"/>
      <history>
        <date date-type="received"><string-date>2 September 2012</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2012 Copyright WSSET</copyright-statement>
        <copyright-year>2012</copyright-year>
      </permissions>
      <abstract><p>Geothermal heat pumps (GSHPs), or direct expansion (DX) ground source heat pumps, are a highly efficient renewable energy technology, which uses the earth, groundwater or surface water as a heat source when operating in heating mode or as a heat sink when operating in a cooling mode. It is receiving increasing interest because of its potential to reduce primary energy consumption and thus reduce emissions of GHGs. The main concept of this technology is that it utilises the lower temperature of the ground (approximately &lt;32°C), which remains relatively stable throughout the year, to provide space heating, cooling and domestic hot water inside the building area. The main goal of this study is to stimulate the uptake of the GSHPs. Recent attempts to stimulate alternative energy sources for heating and cooling of buildings has emphasised the utilisation of the ambient energy from ground source and other renewable energy sources. The purpose of this study, however, is to contribute to the reduction of energy consumption in buildings, identify GSHPs as an environmental friendly technology able to provide efficient utilisation of energy in the buildings sector, promote using GSHPs applications as an optimum means of heating and cooling, and to present typical applications and recent advances of DX GSHPs. The study highlighted the potential energy saving that could be achieved through the use of ground energy sources. It also focuses on the optimisation and improvement of the operation conditions of the heat cycle and performance of the DX GSHP. It is concluded that the direct expansion of GSHP, combined with the ground heat exchanger in foundation piles and the seasonal thermal energy storage from solar thermal collectors, is extendable to more comprehensive applications.</p></abstract>
      <conference>
        <conf-date>2 to 5 September 2012</conf-date>
        <conf-name>11th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2012</conf-acronym>
        <conf-num>11</conf-num>
        <conf-loc>Vancouver, Canada</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">Riffat, S.B., Boukhanouf, R., and Srivastava, N.C. Design and modelling of an adsorption system for heating and cooling applications. Proceedings of the 1st International Conference on Sustainable Energy Technologies, p.70-78, Porto, Portugal, 12-14 June 2002.</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">ASHRAE. Commercial/Institutional Ground Source Heat Pump Engineering Manual. American Society of heating, Refrigeration and Air-conditioning Engineers, Inc. Atlanta, GA: USA. 1995.</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">Kavanaugh, S., Rafferty, K. Ground source heat pumps. Design of Geothermal Systems for Commercial and Institutional Buildings. American Society of heating, Refrigeration and Air-conditioning Engineers, Inc. Atlanta, GA: USA. 1997.</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">Austin, W.A., Yavuzturk, C. and Spitler, J.D. Development of an in situ system and analysis procedure for measuring ground thermal properties. ASRAE Transactions 106 (1). 2000.</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">Fetter, C.W. Determination of the direction of ground-water flow. Ground Water Monitoring Review, No. 3, pp. 28-31. 1981.</mixed-citation>
      </ref>
      <ref id="ref-r6">
        <mixed-citation publication-type="journal">Isiorho, S.A., and Meyer, J.H. The effects of bag type and metre size on seepage metre measurements. Ground Water 37 (3): 411-413. 1999.</mixed-citation>
      </ref>
      <ref id="ref-r7">
        <mixed-citation publication-type="journal">Freeze, R.A., and Cherry, .A. Guest Editorial — What Has Gone Wrong. Ground Water, volume 27, No. 4, July- August 1989.</mixed-citation>
      </ref>
      <ref id="ref-r8">
        <mixed-citation publication-type="journal">Eggen, G. Ground temperature measurements. Oslo. 1990.</mixed-citation>
      </ref>
    </ref-list>
  </back>
</article>