      <title-group><article-title>Energy Efficient Wall Systems for Mid-Rise Wood Frame Buildings</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Zaman</surname><given-names>Hamid</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Mutsuddy</surname><given-names>Rupak</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Singh</surname><given-names>Gurjeet</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Gul</surname><given-names>Mustafa</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Yu</surname><given-names>Haitao</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Al-Hussein</surname><given-names>Mohamed</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">Univ. of Alberta, Dept. of Civil &amp; Env. Eng., 9105 116th St. Edmonton, AB, Canada T6G 2W2</aff>
      <aff id="aff2">Landmark Group of Builders, 9765 54 Ave., Edmonton, AB, Canada T6E 5J4</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>02</day><month>09</month><year>2012</year></pub-date>
      <volume>11</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-1-995850-02-3</isbn>
      <fpage>2148</fpage>
      <lpage>2159</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2012.229"/>
      <history>
        <date date-type="received"><string-date>2 September 2012</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2012 Copyright WSSET</copyright-statement>
        <copyright-year>2012</copyright-year>
      </permissions>
      <abstract><p>An effective option to provide more affordable housing and promote urban density growth is increasing the allowable number of floors in residential light wood frame buildings from four floors to six floors. However, more supporting evidence is needed to demonstrate that this type of construction meets building code performance requirements. The study presents an overview of the research conducted at the University of Alberta to evaluate the thermal resistance performance of some of the potential energy efficient wall systems for mid-rise wood frame buildings. Firstly, some potential wall systems are selected for investigation based on a number of considerations, such as current practice, preliminary structural analysis, and expected energy performance. After preliminary structural analysis of the selected wall systems, they are manufactured and employed for field testing. Several sensors such as heat flux sensors, thermocouples and humidity sensors are installed on the wall systems for long term monitoring of the energy efficiency of the wall systems in severe weather conditions of Alberta. The proposed wall systems have also been tested in the laboratory for their structural capacities. This paper presents the thermal resistance and structural capacity test results of three types of wall systems that may be suitable for mid-rise wood frame structures: (i) 2”x6” (38 mm x 140 mm) staggered with12” (304.8 mm) spacing, (ii) 2”x6” (38 mm x 140 mm) staggered with 8” (203.2 mm) spacing, and (iii) 2”x8” (38 mm x 184 mm) conventional with 12” (304.8 mm) spacing.</p></abstract>
      <conference>
        <conf-date>2 to 5 September 2012</conf-date>
        <conf-name>11th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2012</conf-acronym>
        <conf-num>11</conf-num>
        <conf-loc>Vancouver, Canada</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
    <ref-list>
      <ref id="ref-r1">
        <mixed-citation publication-type="journal">APEGBC. 2011. Structural, Fire Protection and Building Envelope Professional Engineering Services for 5 and 6 Storey Wood Frame Residential Building Projects (Mid-Rise Buildings). APEGBC Technical and Practice Bulletin.</mixed-citation>
      </ref>
      <ref id="ref-r2">
        <mixed-citation publication-type="journal">ASTM C1046-95 (Reapproved 2007). Standard Practice for In-Situ Measurement of Heat Flux and Temperature on Building Envelope Components. ASTM International.</mixed-citation>
      </ref>
      <ref id="ref-r3">
        <mixed-citation publication-type="journal">ASTM C1155-95 (Reapproved 2007). Standard Practice for Determining Thermal Resistance of Building Envelope Components from In-Situ Data. ASTM International, PA, USA.</mixed-citation>
      </ref>
      <ref id="ref-r4">
        <mixed-citation publication-type="journal">ASTM E72-05. 2005. Standard Test Method for Conducting Strength Test of Panels for Building Construction. ASTM International, PA, USA.</mixed-citation>
      </ref>
      <ref id="ref-r5">
        <mixed-citation publication-type="journal">Canadian Wood Council. 2002. Wood-Frame Housing – A North American Marvel. Building Performance Series no. 4. http://www.cwc.ca/documents/durability/BP4_WoodFrameHousing.pdf. Accessed on July 12, 2012.</mixed-citation>
      </ref>
      <ref id="ref-r6">
        <mixed-citation publication-type="journal">Hendron, R., Engebrecht, C. 2010. Building America Research Benchmark Definition: Updated December 2009. National Renewable Energy Laboratory. http://www.nrel.gov/docs/fy10osti/47246.pdf. Accessed on July 12, 2012.</mixed-citation>
      </ref>
      <ref id="ref-r7">
        <mixed-citation publication-type="journal">Karagiozis, A., Salonvaara, M. 2001. Hygrothermal System-performance of a Whole Building. Building and Environment, vol. 36, pp 779-787.</mixed-citation>
      </ref>
      <ref id="ref-r8">
        <mixed-citation publication-type="journal">Kossecka, E., Kosny, J. 2002. Influence of Insulation Configuration on Heating and Cooling Loads in a Continuously Used Building. Energy and Buildings, vol. 34, pp 321-331.</mixed-citation>
      </ref>
      <ref id="ref-r9">
        <mixed-citation publication-type="journal">Morrison Hershfield. 2011. Thermal Performance of Building Envelope Details for Mid- and High-Rise Buildings. Technical report presented to ASHRAE Inc.</mixed-citation>
      </ref>
      <ref id="ref-r10">
        <mixed-citation publication-type="journal">National Energy Board. 2011. Canada’s Energy Future: Energy Supply and Demand Projections to 2035 – Energy Market Assessment 2011. http://www.neb-one.gc.ca/clf-nsi/rnrgynfmtn/nrgyrprt/nrgyftr/2011/nrgsppldmndprjctn2035-eng.pdf. Accessed on July 12, 2012.</mixed-citation>
      </ref>
      <ref id="ref-r11">
        <mixed-citation publication-type="journal">Sadineni, S.B., Madala, S., Boehm, R.F. 2011. Passive Building Energy Savings: A Review of Building Envelope Components. Renewable and Sustainable Energy Reviews, vol. 15, pp 3617-3631.</mixed-citation>
      </ref>
      <ref id="ref-r12">
        <mixed-citation publication-type="journal">Sozer, H. 2010. Improving Energy Efficiency through the Design of the Building Envelope. Building and Environment, vol. 45, pp 2581-2593.</mixed-citation>
      </ref>
      <ref id="ref-r13">
        <mixed-citation publication-type="journal">Statistics Canada. 2011. Households and the Environment: Energy Use. Catalogue no: 11-526-SWE.</mixed-citation>
      </ref>
      <ref id="ref-r14">
        <mixed-citation publication-type="journal">Straube, J., Onysko, D., Schumacher, C. 2002. Methodology and Design of Field Experiments for Monitoring the Hygrothermal Performance of Wood Frame Enclosure. Journal of Building Physics, vol. 26(2), pp 123-151.</mixed-citation>
      </ref>
      <ref id="ref-r15">
        <mixed-citation publication-type="journal">Straube, J., Smegal, J. 2011. Building America Special Research Project: High-R Walls Case Study Analysis. Building Science Corporation. Research Report 0903.</mixed-citation>
      </ref>
      <ref id="ref-r16">
        <mixed-citation publication-type="journal">Thue, J.V., Skogstad, H.B. 1996. Wood Frame Walls in Cold Climate – Vapour Barrier Requirements. Journal of Building Physics, vol. 20(1), pp 63-75.</mixed-citation>
      </ref>
      <ref id="ref-r17">
        <mixed-citation publication-type="journal">U.S. Energy Information Administration. 2011. Annual Energy Review 2010. DOE/EIA-0384(2010. http://www.eia.gov/totalenergy/data/annual/pdf/aer.pdf. Accessed on July 12, 2012.</mixed-citation>
      </ref>
      <ref id="ref-r18">
        <mixed-citation publication-type="journal">Zhao, J., Plagge, R., Nicolai, A., Grunewald, J., Zhang, J.S. 2011. Stochastic Study of Hygrothermal Performance of a Wall Assembly – The Influence of Material Properties and Boundary Conditions. HVAC&amp;R Research, vol. 17(4), pp 591-601.</mixed-citation>
      </ref>
    </ref-list>