<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2012.250</article-id>
      <article-id pub-id-type="publisher-id">2012.250</article-id>
      <title-group><article-title>Measurement of Cooling Effect from Evaporator of a Small Scale Single Bed Desalination System</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Israr</surname><given-names>Farrukh</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Hyun</surname><given-names>Joon Ho</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Oh</surname><given-names>Seung Jin</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Ng</surname><given-names>Kim Choon</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Chun</surname><given-names>Wongee</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">Department of Nuclear and Energy engineering, Jeju National University, Jeju 690-756, Korea</aff>
      <aff id="aff2">Department of Mechanical Engineering, National University of Singapore, 10 Kent Ridge Crescent, Singapore 119260</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>02</day><month>09</month><year>2012</year></pub-date>
      <volume>11</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-1-995850-02-3</isbn>
      <fpage>2368</fpage>
      <lpage>2372</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2012.250"/>
      <history>
        <date date-type="received"><string-date>2 September 2012</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2012 Copyright WSSET</copyright-statement>
        <copyright-year>2012</copyright-year>
      </permissions>
      <abstract><p>A lab-scale, batch-type single bed adsorption desalination (AD) system, employing silica gel-water as adsorber-adsorbate pair has been developed. The main advantages of the AD cycle are; (i) Its ability to utilize low temperature waste or renewable heat source (ii) has almost no major moving parts, (ii) low maintenance and (iii) environmental friendly. The extent of effective cooling from evaporator in terms of evaporation based co-efficient of performance (COP) and specific cooling capacity (SCC) has been estimated with respect to inlet coolant water temperatures. In the current study, it has been observed that the overall heat transfer co-efficient (U), specific cooling capacity (SCC) and co-efficient of performance (COP) are influenced linearly by the inlet coolant temperature inside the evaporator.</p></abstract>
      <conference>
        <conf-date>2 to 5 September 2012</conf-date>
        <conf-name>11th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2012</conf-acronym>
        <conf-num>11</conf-num>
        <conf-loc>Vancouver, Canada</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>