<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2013.006</article-id>
      <article-id pub-id-type="publisher-id">2013.006</article-id>
      <title-group><article-title>Measuring energy efficiency for elevated tank water supply systems</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author" corresp="yes">
        <name><surname>Wong</surname><given-names>L.T.</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>beltw@polyu.edu.hk</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Mui</surname><given-names>K.W.</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Cheung</surname><given-names>C.T.</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">Department of Building Services Engineering, The Hong Kong Polytechnic University, Hong Kong China</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>26</day><month>08</month><year>2013</year></pub-date>
      <volume>12</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">9789881543950</isbn>
      <fpage>84</fpage>
      <lpage>90</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2013.006"/>
      <history>
        <date date-type="received"><string-date>26 August 2013</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2013 Copyright WSSET</copyright-statement>
        <copyright-year>2013</copyright-year>
      </permissions>
      <abstract><p>Energy efficiency of water supply systems in high-rise residential buildings becomes a concern for sustainable development nowadays. This paper presents an energy efficiency evaluation measure for water supply system designs that utilizes the potential energy of the water demands at end-users in buildings divided by the pumping energy required. A mathematical model is formulated for optimizing pumping energy through the arrangement of water tanks in a building. Measurement data of some high-rise residential buildings in Hong Kong are employed to demonstrate the model applicability. The results show the energy efficiency of many existing high-rise water supply systems is about 0.24 and can be improved to 0.26-0.30 via water storage tank relocations, corresponding to an annual electricity saving potential of 192 TJ, a 0.1% of the total annual electricity consumption in Hong Kong. The proposed measure of energy efficiency can be a parameter of designing sustainable water supply systems for buildings.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Building</kwd>
        <kwd>water supply</kwd>
        <kwd>energy efficiency</kwd>
        <kwd>water consumption</kwd>
        <kwd>storage tank location</kwd>
      </kwd-group>
      <conference>
        <conf-date>26 to 29 August 2013</conf-date>
        <conf-name>12th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2013</conf-acronym>
        <conf-num>12</conf-num>
        <conf-loc>Hong Kong, China</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>
