<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2013.098</article-id>
      <article-id pub-id-type="publisher-id">2013.098</article-id>
      <title-group><article-title>Performance of natural and forced convection heat pipe solar water heaters.</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Tong</surname><given-names>Wei-Li</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Ong</surname><given-names>Kok-Seng</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
        <email>skong@utar.edu.my</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Ng</surname><given-names>Wei-Sheng</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">Monash University Sunway Campus, Jalan Lagoon Selatan, 46150 Bandar Sunway, Selangor, Malaysia</aff>
      <aff id="aff2">Universiti Tunku Abdul Rahman, Jalan Universiti, Bandar Barat, 31900 Kampar, Perak, Malaysia</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>26</day><month>08</month><year>2013</year></pub-date>
      <volume>12</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">9789881543950</isbn>
      <fpage>906</fpage>
      <lpage>915</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2013.098"/>
      <history>
        <date date-type="received"><string-date>26 August 2013</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2013 Copyright WSSET</copyright-statement>
        <copyright-year>2013</copyright-year>
      </permissions>
      <abstract><p>The thermal performances of the evacuated heat pipe solar water heaters operated under natural and force convection were tested. Three evacuated heat pipe solar collectors were connected in series and coupled with an insulated storage tank. Force convection system utilized a circulation pump while the natural convection system operated under thermal buoyancy. The results showed that the natural convection system performed better than the forced convection system due to the difference in the performance of the heat pipe. A natural convection system is able to provide the heat pipe condenser with sufficient cooling water drained from the lower section of the storage tank. Temperature stratification within the storage tank prevents the fast mixing of the heated water returning from the solar collectors with the cold water. Hence, constant low temperature cooling water can be supplied to the condenser to absorb heat energy transferred by heat pipe. On the other hand, force convection system will have a well mixed water temperature within the storage tank. As the circulation pump circulates the heated water back to the solar collectors, the heat transfer within the heat pipe will be decreased due to the insufficient cooling of the condenser.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Heat pipe</kwd>
        <kwd>solar water heater</kwd>
        <kwd>natural convection</kwd>
        <kwd>force convection</kwd>
      </kwd-group>
      <conference>
        <conf-date>26 to 29 August 2013</conf-date>
        <conf-name>12th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2013</conf-acronym>
        <conf-num>12</conf-num>
        <conf-loc>Hong Kong, China</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>