<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2013.108</article-id>
      <article-id pub-id-type="publisher-id">2013.108</article-id>
      <title-group><article-title>Experimental research of a fin-tube type internally-cooled liquid desiccant dehumidifier</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Luo</surname><given-names>Yimo</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author" corresp="yes">
        <name><surname>Shao</surname><given-names>Shuangquan</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
        <email>shaoshq@mail.ipc.ac.cn</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Xu</surname><given-names>Hongbo</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Tian</surname><given-names>Changqing</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Yang</surname><given-names>Hongxing</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">Renewable Energy Research Group (RERG), Department of Building Services Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong, P. R. China</aff>
      <aff id="aff2">Technical Institute of Physics and Chemistry, Chinese Academy of Sciences, Beijing 100190, P. R. China</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>26</day><month>08</month><year>2013</year></pub-date>
      <volume>12</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">9789881543950</isbn>
      <fpage>1001</fpage>
      <lpage>1007</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2013.108"/>
      <history>
        <date date-type="received"><string-date>26 August 2013</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2013 Copyright WSSET</copyright-statement>
        <copyright-year>2013</copyright-year>
      </permissions>
      <abstract><p>As an essential part of the liquid desiccant air conditioning system, the dehumidifier has great impact on the performance of the whole system. This paper studies the performance of a cross-flow internally-cooled dehumidifier based on the fin-tube heat exchanger. The influence of various inlet parameters on the dehumidification performance has been analyzed in detail, which will provide useful information for further study. Compared with popular dehumidifiers in literatures, it is found that the dehumidifier of this work performs well in terms of dehumidification rate and efficiency. Moreover, due to its large specific surface area, high corrosion resistance and light weight, the dehumidifier possesses high efficiency with small size, and hence has the possibility to make the system miniaturization.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>dehumidifier</kwd>
        <kwd>internally-cooled</kwd>
        <kwd>fin-tube type</kwd>
        <kwd>miniaturization</kwd>
      </kwd-group>
      <conference>
        <conf-date>26 to 29 August 2013</conf-date>
        <conf-name>12th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2013</conf-acronym>
        <conf-num>12</conf-num>
        <conf-loc>Hong Kong, China</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>
