<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2013.252</article-id>
      <article-id pub-id-type="publisher-id">2013.252</article-id>
      <title-group><article-title>Study on the impact of cool roofs on energy consumption at a railway station</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author" corresp="yes">
        <name><surname>Ma</surname><given-names>Weiwu</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>maweiwu@csu.edu.cn</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Wang</surname><given-names>Xiaozong</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Li</surname><given-names>Liqing</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Cheng</surname><given-names>Jia</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Yu</surname><given-names>Leimu</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Yao</surname><given-names>Xiaolong</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">School of Energy Science and Engineering, Central South University, Changsha 410083, China</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>26</day><month>08</month><year>2013</year></pub-date>
      <volume>12</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">9789881543950</isbn>
      <fpage>2229</fpage>
      <lpage>2240</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2013.252"/>
      <history>
        <date date-type="received"><string-date>26 August 2013</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2013 Copyright WSSET</copyright-statement>
        <copyright-year>2013</copyright-year>
      </permissions>
      <abstract><p>The solar radiation through a roof has considerable influence on air-conditioning energy consumption and indoor lighting in a single-story large volume building, for example, a railway station. The roof reflectance and skylight shade reflectance are two significant factors which affect solar radiation from roof and natural lighting. After a qualitative analysis of the effect of cool roofs on building performance, a model is built for a railway station using EnergyPlus. The model was then verified with field data, and applied to study the effect of cool roof reflectance and skylight shade reflectance on the installed capacity of the air-conditioning system, lighting energy consumption and indoor thermal comfort in different climate regions. The results show that with the appropriate utilization of non-transparent cool roof, high reflectance can help to reduce cooling energy consumption and installed capacity of the air-conditioning system effectively, and to improve the indoor thermal comfort in the summer. However, more energy is consumed in winter, resulting in more total energy consumption during the whole year. On the other hand, high reflectivity of the skylights reduces energy consumption for cooling in summer, and only slightly increases energy consumption for heating and lighting, which saves vast energy in the whole year. Moreover, the inherent properties of the roof structure and local climates should be considered when employing the cool roof technology in practice.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Cool roof</kwd>
        <kwd>Railway station</kwd>
        <kwd>Roof reflectance</kwd>
        <kwd>Skylight shade reflectance</kwd>
        <kwd>Energy consumption</kwd>
      </kwd-group>
      <conference>
        <conf-date>26 to 29 August 2013</conf-date>
        <conf-name>12th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2013</conf-acronym>
        <conf-num>12</conf-num>
        <conf-loc>Hong Kong, China</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>
