<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2014.080</article-id>
      <article-id pub-id-type="publisher-id">2014.080</article-id>
      <title-group><article-title>Analysis on Preheating Effect of Double Skin Facade Connected to Outdoor Air Path of Air Handling Unit</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author" corresp="yes">
        <name><surname>Cho</surname><given-names>Soo</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>scho@kier.re.kr</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Sung</surname><given-names>Uk-Joo</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Lim</surname><given-names>Sang-Hoon</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">Korea Institute of Energy Research, 152 Gajeong-ro, Yuseong-gu, Daejeon 305-343, Korea</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>25</day><month>08</month><year>2014</year></pub-date>
      <volume>13</volume>
      <isbn publication-format="electronic">978-1-995850-01-6</isbn>
      <fpage>1</fpage>
      <lpage>4</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2014.080"/>
      <history>
        <date date-type="received"><string-date>25 August 2014</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2014 Copyright WSSET</copyright-statement>
        <copyright-year>2014</copyright-year>
      </permissions>
      <abstract><p>In this study, temperature distribution and amount of preheating generation of intermediate space of multi-stories type double skin facade connected to outdoor air(OA) duct of air handling unit(AHU) are analyzed by actual measurement in winter season. Also, the design plan for improving preheating effect is suggested through the measurement results. As the results of this study, envelope and outdoor air load are quite reduced by proper control of OA airflow rate in utilizing preheated OA via intermediate space of DSF.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Double skin façade</kwd>
        <kwd>Preheating</kwd>
        <kwd>Heating load</kwd>
        <kwd>Air handling unit</kwd>
      </kwd-group>
      <conference>
        <conf-date>25 to 28 August 2014</conf-date>
        <conf-name>13th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2014</conf-acronym>
        <conf-num>13</conf-num>
        <conf-loc>Geneva, Switzerland</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>