<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2015.089</article-id>
      <article-id pub-id-type="publisher-id">2015.089</article-id>
      <title-group><article-title>Research on the compressor test rig for refrigerant drop-in experiment</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Lee</surname><given-names>Gilbong</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Kim</surname><given-names>Joo-Sang</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Cho</surname><given-names>Junhyun</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Ra</surname><given-names>Ho-Sang</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Lee</surname><given-names>Young-Soo</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">Thermal Energy Conversion Laboratory, Korea Institute of Energy Research, 152, Gajeong-ro, Yuseong-gu, Daejeon, Korea</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>06</day><month>07</month><year>2016</year></pub-date>
      <volume>14</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-0-85358-313-4</isbn>
      <fpage>891</fpage>
      <lpage>896</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2015.089"/>
      <history>
        <date date-type="received"><string-date>6 July 2016</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2015 Copyright WSSET</copyright-statement>
        <copyright-year>2016</copyright-year>
      </permissions>
      <abstract><p>This study is on the compressor test rig for refrigerant change test. Increasing the production temperature is one of the main research topics of heat pump and for that compressor plays the key role. To ensure the reliability of compressor, both analytic and experimental approaches would be used. This study takes the experimental approach to check the reliability. Steam generation is the target operation condition. R245fa is selected as working fluid since it has good characteristics under the temperature range for steam generation. For effective experiments test rig based on bypass cycle is constructed. Long term experiment on refrigerant change is under operation. Change of lubricant will be scheduled later.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Compressor</kwd>
        <kwd>Heat pump</kwd>
        <kwd>Steam Generation</kwd>
      </kwd-group>
      <conference>
        <conf-date>25 to 27 August 2015</conf-date>
        <conf-name>14th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2015</conf-acronym>
        <conf-num>14</conf-num>
        <conf-loc>Nottingham, United Kingdom</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>
