<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2015.095</article-id>
      <article-id pub-id-type="publisher-id">2015.095</article-id>
      <title-group><article-title>A comparative analysis of the maisotsenko cycle based air-conditioning systems: ejector cooling vs. desiccant</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Buyadgie</surname><given-names>Olexiy</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <xref ref-type="aff" rid="aff2"/>
        <email>buyadgie@wilson-ukraine.com</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Buyadgie</surname><given-names>Dmytro</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Drakhnia</surname><given-names>Oleksii</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Maisotsenko</surname><given-names>Valeriy</given-names></name>
        <xref ref-type="aff" rid="aff3"/>
        <email>vm@coolerado.com</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Miyazaki</surname><given-names>Takahiko</given-names></name>
        <xref ref-type="aff" rid="aff4"/>
        <email>tmiyazak@kyudai.jp</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Chamchine</surname><given-names>Andrei</given-names></name>
        <xref ref-type="aff" rid="aff5"/>
        <email>achamchine@uclan.ac.uk</email>
      </contrib>
      <aff id="aff1">V.S. Martynovsky Institute of Refrigeration, Cryogenic Technologies and Eco Energetics. 1/3, Dvoryanskaya Street, 65023 Odessa, Ukraine</aff>
      <aff id="aff2">Wilson (Ejector Laboratory), 15/13, Mikhailiv’ska Street, 65005, Odessa, Ukraine</aff>
      <aff id="aff3">Coolerado Corp. and Idalex Inc. 4430 Glencoe Street, Denver, CO 80216, USA</aff>
      <aff id="aff4">Thermal Energy Conversion System Laboratory (TECSL), Faculty of Engineering Sciences, Kyushu University, 6-1 Kasuga koen, Kasuga-shi, Fukuoka 816-8580, Japan</aff>
      <aff id="aff5">University of Central Lancashire, Preston PR1 2HE, UK</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>06</day><month>07</month><year>2016</year></pub-date>
      <volume>14</volume>
      <issue>2</issue>
      <isbn publication-format="electronic">978-0-85358-314-1</isbn>
      <fpage>65</fpage>
      <lpage>74</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2015.095"/>
      <history>
        <date date-type="received"><string-date>6 July 2016</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2015 Copyright WSSET</copyright-statement>
        <copyright-year>2016</copyright-year>
      </permissions>
      <abstract><p>The numerous researches of the Maisotsenko cycle (M-cycle) application for air-conditioning purposes prove 3 to 10 times (depending on air humidity) energy saving compared to the conventional vapour-compression systems. Another important value of air-conditioning through the M-cycle is the air displacement process that serves to supply fresh air into the conditioned premises continuously at the fixed energy input. Being considered as a pure heat recuperative process, the M-cycle cooling requires water makeup that is obviously high in the dry climate zones. Conversely, in the humid zones, where absolute humidity exceeds 11g/kg of the dry air, the M-cycle based air-conditioners are unable to meet the air dehumidification challenge and require the conventional or state-of-the art technologies to remove the excess moisture from the processed air before its substantial cooling to the set temperatures. In order to validate the performance of the M-cycle based air-conditioners in the humid zones and minimize the overall energy input for cooling and dehumidification processes, a comparative analysis of the latest desiccant dehumidifiers and ejector cooling systems was performed. The study is devoted to disclose the pros and cons of the existed schemes of the M-cycle based cooling systems for the habitant and technological conditions. Alternatively, it was proposed the hybrid M-cycle/desiccant/ejector air-conditioner that may serve to be one of the most energy efficient cooling system for the humid climate conditions, where 85% of the world's air-cooling demand is located.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>M-Cycle</kwd>
        <kwd>ejector</kwd>
        <kwd>refrigeration</kwd>
        <kwd>humid</kwd>
        <kwd>desiccant</kwd>
      </kwd-group>
      <conference>
        <conf-date>25 to 27 August 2015</conf-date>
        <conf-name>14th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2015</conf-acronym>
        <conf-num>14</conf-num>
        <conf-loc>Nottingham, United Kingdom</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>
