<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2016.030</article-id>
      <article-id pub-id-type="publisher-id">2016.030</article-id>
      <title-group><article-title>In-situ thermal performance monitoring of a novel domestic heat recovery unit</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author" corresp="yes">
        <name><surname>Cuce</surname><given-names>Pinar Mert</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <xref ref-type="aff" rid="aff2"/>
        <email>Pinar.Mertcuce@nottingham.ac.uk</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Cuce</surname><given-names>Erdem</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <xref ref-type="aff" rid="aff3"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Bayraktar</surname><given-names>Kemal Gani</given-names></name>
        <xref ref-type="aff" rid="aff4"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Riffat</surname><given-names>Saffa</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">Department of Architecture and Built Environment, Faculty of Engineering, University of Nottingham, University Park, NG7 2RD, Nottingham, United Kingdom</aff>
      <aff id="aff2">Republic of Turkey Ministry of National Education, Ankara, Turkey</aff>
      <aff id="aff3">Department of Mechanical Engineering, Faculty of Engineering, University of Bayburt, 69000, Bayburt, Turkey</aff>
      <aff id="aff4">Izocam Tic. ve San. A.S., Altaycesme Mah., Oz Sokak, No:19, Kat:3-5-6, P.K. 34843, Istanbul, Turkey</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>22</day><month>01</month><year>2021</year></pub-date>
      <volume>15</volume>
      <issue>1</issue>
      <isbn publication-format="electronic">978-0-85358-338-7</isbn>
      <fpage>263</fpage>
      <lpage>268</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2016.030"/>
      <history>
        <date date-type="received"><string-date>22 January 2021</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2016 Copyright WSSET</copyright-statement>
        <copyright-year>2021</copyright-year>
      </permissions>
      <abstract><p>Heat recovery systems are highly preferred in today’s world for mitigating the heating and cooling demands of buildings. The main goal of any heat recovery technology utilised in the building sector can be assertd to reduce energy consumption due to heating, ventilation and air-conditioning (HVAC) systems. Several theoretical and simulation works have been done to date in literature. However, works dealing with performance assessment in real operating conditions are very limited. Therefore in this study, a comprehensive thermal comfort analysis of a test house integrated with a novel polycarbonate heat exchanger was carried out. Pre- and post-retrofit, temperature, relative humidity and CO2 measurements were conducted during a week in winter. The results from the pre-retrofit case clearly revealed that the internal CO2 concentration did not cover a desirable range due to a lack of ventilation in the test house. However, following the integration of the novel ventilation system, CO2 concentrations were found to vary notably from 350 to 400 ppm which was satisfactory and corresponded to the actual comfort conditions for indoor environments. Another achievement was that the average relative humidity in the post-retrofit case was found to be 57%, which was good as it was notably higher at the pre-retrofit stage.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>residential buildings</kwd>
        <kwd>polycarbonate</kwd>
        <kwd>heat exchanger</kwd>
        <kwd>waste heat recovery</kwd>
        <kwd>HVAC</kwd>
      </kwd-group>
      <conference>
        <conf-date>19 to 22 July 2016</conf-date>
        <conf-name>15th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2016</conf-acronym>
        <conf-num>15</conf-num>
        <conf-loc>Singapore</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>
