<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2017.034</article-id>
      <article-id pub-id-type="publisher-id">2017.034</article-id>
      <title-group><article-title>Influence of Heat Exchangers and Compressor Performance on Domestic Split-Type Air Conditioner System Performance Monitoring and Prediction</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Bantan Mafor</surname><given-names>Glory</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>bantanmaforglory@gmail.com</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Loh Tangwe</surname><given-names>Stephen</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>stangwe@ufh.ac.za</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Simon</surname><given-names>Michael</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>msimon@ufh.ac.za</email>
      </contrib>
      <aff id="aff1">Fort Hare Institute of Technology, University of Fort Hare, Private Bag x1314, 5700, Alice, South Africa</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>13</day><month>07</month><year>2017</year></pub-date>
      <volume>16</volume>
      <isbn publication-format="electronic">9791220022033</isbn>
      <fpage>1</fpage>
      <lpage>8</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2017.034"/>
      <history>
        <date date-type="received"><string-date>13 July 2017</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2017 Copyright WSSET</copyright-statement>
        <copyright-year>2017</copyright-year>
      </permissions>
      <abstract><p>Monitoring and predicting the performance of air conditioning (AC) systems have been a daunting task. This is as a result of system operation complexity owing to the huge number of dynamic factors influencing the system’s operation. Nevertheless, there is a dire need to monitor and predict the performance of the system in order to ascertain with high level of certainty the energetic, financial and human comfort impact of this technology. It is in this light that this paper analyses the performance of main AC system components in order to qualitatively and quantitatively ascertain how their performances influence the overall AC performance and to what degree of accuracy these factors can predict system performance. This was achieved via investigating the influence of Rcom, Pcon and Pevp on the AC heating and cooling COP and energy consumed (COPh, COPc, Eh and Ec). Data was obtained from an experimental set up installed in a residential home in Alice, Eastern Cape Province, South Africa. It was observed that for this system, COP is greatly influenced by the performance of the heat exchangers more than performance of compressor. Energy consumed by the system is greatly influenced by the compressor performance or efficiency. Among the two heat exchanger performances, heating energy is affected by condenser performance more, while cooling energy is affected by evaporator performance more. The developed models had correlation and determination coefficient range up to 0.98, hence, a high degree of proximity between predicted and actual response. This goes to show that heat exchangers and compressor performance do not only greatly influence system performance but can also be used to accurately monitor and predict the performance of a domestic split-type AC with an eminent degree of accuracy.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>compressor</kwd>
        <kwd>COP</kwd>
        <kwd>energy</kwd>
        <kwd>heat exchangers</kwd>
        <kwd>performance</kwd>
        <kwd>regression model</kwd>
        <kwd>split-type AC</kwd>
      </kwd-group>
      <conference>
        <conf-date>17 to 20 July 2017</conf-date>
        <conf-name>16th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2017</conf-acronym>
        <conf-num>16</conf-num>
        <conf-loc>Bologna, Italy</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>