<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2017.209</article-id>
      <article-id pub-id-type="publisher-id">2017.209</article-id>
      <title-group><article-title>Preliminary Study on the Effect of Dry/wet Cooling Combinations for the Sustainable Management of Water of Cooling Tower</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Lee</surname><given-names>Gilbong</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>giblee@kier.re.kr</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Ra</surname><given-names>Ho-Sang</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>hsra@kier.re.kr</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Lee</surname><given-names>Beomjoon</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>beomjoon.lee@kier.re.kr</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Lee</surname><given-names>Young-Soo</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>yslee@kier.re.kr</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Roh</surname><given-names>Chul Woo</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>chulwoo.roh@kier.re.kr</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Baik</surname><given-names>Young-Jin</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>twinjin@kier.re.kr</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Cho</surname><given-names>Junhyun</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>jhcho@kier.re.kr</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Shin</surname><given-names>Hyungki</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>hkeewind@kier.re.kr</email>
      </contrib>
      <aff id="aff1">Thermal Energy System Laboratory, Korea Institute of Energy Research, Korea</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>13</day><month>07</month><year>2017</year></pub-date>
      <volume>16</volume>
      <isbn publication-format="electronic">9791220022033</isbn>
      <fpage>1</fpage>
      <lpage>5</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2017.209"/>
      <history>
        <date date-type="received"><string-date>13 July 2017</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2017 Copyright WSSET</copyright-statement>
        <copyright-year>2017</copyright-year>
      </permissions>
      <abstract><p>Recently, sustainable management of water has received a lot of interest since the shortage of it has become one of major environmental issues. Power plants eject tremendous amount of condensation heat to generate electricity. Water is the most commonly used heat transfer materials. During the heat transfer process, large amount of water is evaporated into the air. This causes severe water management problems around the world. Dry cooling is an alternative cooling method, but it may potentially cause efficiency degrade. In this paper, the combination of dry/wet cooling methods are considered as a candidate for the sustainment of water resource and efficiency. The yearly requirements of design parameters of each cooling types is analysed. Based on the results, design points will be determined.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Power plant</kwd>
        <kwd>wet cooling</kwd>
        <kwd>dry cooling</kwd>
        <kwd>water management</kwd>
      </kwd-group>
      <conference>
        <conf-date>17 to 20 July 2017</conf-date>
        <conf-name>16th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2017</conf-acronym>
        <conf-num>16</conf-num>
        <conf-loc>Bologna, Italy</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>