<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2018.148</article-id>
      <article-id pub-id-type="publisher-id">2018.148</article-id>
      <title-group><article-title>Optimisation of hierarchical protection and control system for Smart Substation</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Xiao</surname><given-names>Shiyi</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <xref ref-type="aff" rid="aff2"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Wu</surname><given-names>Tiezhou</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <xref ref-type="aff" rid="aff3"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Yang</surname><given-names>Fanfan</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Guo</surname><given-names>Linxin</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <xref ref-type="aff" rid="aff3"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Li</surname><given-names>Yan</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Wang</surname><given-names>Yueyang</given-names></name>
        <xref ref-type="aff" rid="aff4"/>
      </contrib>
      <aff id="aff1">School of Electrical and Electronic Engineering, Hubei University of Technology, Wuhan 430068</aff>
      <aff id="aff2">Anqing power supply company,Anqing,246003</aff>
      <aff id="aff3">Hubei Collaborative Innovation Center for High-efficiency Utilization of Solar Energy, Hubei University of Technology, Wuhan 430068</aff>
      <aff id="aff4">Sifang Protection (Wuhan) Software Ltd., Wuhan,246003</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>28</day><month>02</month><year>2019</year></pub-date>
      <volume>17</volume>
      <issue>3</issue>
      <isbn publication-format="electronic">978-0-85358-327-1</isbn>
      <fpage>195</fpage>
      <lpage>202</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2018.148"/>
      <history>
        <date date-type="received"><string-date>28 February 2019</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2018 Copyright WSSET</copyright-statement>
        <copyright-year>2019</copyright-year>
      </permissions>
      <abstract><p>Smart substation is an important part of smart grid. The safe and stable operation of the grid cannot be separated from the protection equipment. Therefore, it is necessary to optimise the protection control system of substation. Hierarchical protection of power grid includes three levels: prefecture level protection, station area protection and wide area protection. The technology of hierarchical protection is the inevitable product of smart grid development process which is characterized by informatization, automation and interaction. Compared with traditional relay protection, the system has great changes in principle and implementation mode, and its performance also has great progress. In this paper, a new generation of Smart substation hierarchical protection control system architecture is discussed. And the configuration scheme and coordination scheme are proposed to achieve the coordination and unity of relay protection and safe control, in order to adapt to the trend of power grid interconnection and complex, changeable operation requirements. Combining with a practical case of 110kV substation, this paper analyses the protection configuration scheme at prefecture level and station level, and puts forward the optimisation and integration scheme of interval layer equipment and process layer equipment.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>Smart substation</kwd>
        <kwd>Hierarchical protection</kwd>
        <kwd>Prefecture level protection</kwd>
        <kwd>Station area protection</kwd>
      </kwd-group>
      <conference>
        <conf-date>21 to 23 August 2018</conf-date>
        <conf-name>17th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2018</conf-acronym>
        <conf-num>17</conf-num>
        <conf-loc>Wuhan, China</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>
