<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2019.161</article-id>
      <article-id pub-id-type="publisher-id">2019.161</article-id>
      <title-group><article-title>The study on the heat transfer characteristics of the double U-tube pipes underground</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author" corresp="yes">
        <name><surname>Shang</surname><given-names>Yan</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>shangyan@dlut.edu.cn</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Huang</surname><given-names>Xiaowan</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Dong</surname><given-names>Ming</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Li</surname><given-names>Sufen</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Liu</surname><given-names>Xiaohua</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
      </contrib>
      <aff id="aff1">Key Lab. of Ocean Energy Utilization and Energy Conservation of Ministry of Education, Dalian University of Technology, Dalian 116024 P. R. China</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>10</day><month>02</month><year>2020</year></pub-date>
      <volume>18</volume>
      <issue>3</issue>
      <isbn publication-format="electronic">978-0-85358-331-8</isbn>
      <fpage>372</fpage>
      <lpage>379</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2019.161"/>
      <history>
        <date date-type="received"><string-date>10 February 2020</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2019 Copyright WSSET</copyright-statement>
        <copyright-year>2020</copyright-year>
      </permissions>
      <abstract><p>One of the main deployment forms of geothermal energy is the soil source heat pump system. In this paper, the variation of the heat transfer characteristics of the double U-tube heat exchanger underground are analysed based on the soil source heat pump system (SSHP) experimental system, which was installed with six temperature measuring cables with a total of 117 DS18B20 soil temperature measuring points. Based on the same working conditions (the initial soil temperature was 14.5°C, the initial inlet water temperature of the U-tube pipe was 3°C, the flow rate was 120L/h and the corresponding flow velocity was 1.7m/s), the thermal interference of the double U-tube pipes underground was studied during the operation of the soil source heat pump, the soil heat transfer characteristics between single and double U-tube pipes were compared. Furthermore, the effects under different seepage velocity on soil temperature field were studied, the heat transfer rate underground analysed and the variation regulation of heat interference explained. It can be concluded that the thermal radius of the single U-tube system was greater than that of the intersection area of the double U-tube pipes field of the system. The greater the seepage velocity, the greater the radius of action of the buried pipe on the soil along the direction of seepage. The thermal radius was smaller than normal at the direction of vertical to the seepage, and the greater the seepage velocity, the smaller the thermal radius applied by the buried pipe to the soil.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>double-U-tube pipes</kwd>
        <kwd>soil source heat pump</kwd>
        <kwd>performance</kwd>
        <kwd>heat transfer characteristics</kwd>
      </kwd-group>
      <conference>
        <conf-date>20 to 22 August 2019</conf-date>
        <conf-name>18th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2019</conf-acronym>
        <conf-num>18</conf-num>
        <conf-loc>Kuala Lumpur, Malaysia</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>