<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" dtd-version="1.3" article-type="research-article" xml:lang="en">
  <front>
    <journal-meta>
      <journal-title-group><journal-title>SET Proceedings</journal-title></journal-title-group>
      <issn pub-type="epub">2978-4387</issn>
      <publisher><publisher-name>Caravel Press</publisher-name></publisher>
    </journal-meta>
    <article-meta>
      <article-id pub-id-type="doi">10.65582/set.2022.084</article-id>
      <article-id pub-id-type="publisher-id">2022.084</article-id>
      <title-group><article-title>Mechanical ventilator control unit design with a Venturi-type flowmeter</article-title></title-group>
    <contrib-group>
      <contrib contrib-type="author">
        <name><surname>Dönmez</surname><given-names>Aydın Hacı</given-names></name>
        <xref ref-type="aff" rid="aff1"/>
        <email>aydindonmez@halic.edu.tr</email>
      </contrib>
      <contrib contrib-type="author">
        <name><surname>Mutlu</surname><given-names>Yaşar</given-names></name>
        <xref ref-type="aff" rid="aff2"/>
        <email>yasarmutlu@beykent.edu.tr</email>
      </contrib>
      <aff id="aff1">Halic University,15 Temmuz Şehitler Caddesi, No:14/12 34060 Eyüpsultan/Istanbul</aff>
      <aff id="aff2">Beykent University, Ayazağa, Hadım Koruyolu Cd. No:19, 34398 Sarıyer/İstanbul</aff>
    </contrib-group>
      <pub-date publication-format="electronic" date-type="pub"><day>16</day><month>02</month><year>2023</year></pub-date>
      <volume>19</volume>
      <issue>2</issue>
      <isbn publication-format="electronic">978-0-85358-351-6</isbn>
      <fpage>340</fpage>
      <lpage>348</lpage>
      <self-uri xlink:href="https://caravelpress.com/proceedings/set/papers/2022.084"/>
      <history>
        <date date-type="received"><string-date>16 February 2023</string-date></date>
      </history>
      <permissions>
        <copyright-statement>© 2022 Copyright WSSET</copyright-statement>
        <copyright-year>2023</copyright-year>
      </permissions>
      <abstract><p>The importance of the mechanical ventilators has increased as their presence became more of an issue during the COVID-19 pandemic. The air/oxygen control unit is the vital element of the machine that adjusts the air quality according to the patient’s needs. For this purpose, design optimization of a mechanical ventilator control unit was performed. The design procedure was conducted by taking into account safety and flow adjustment considerations. Furthermore, a Venturi-type flowmeter was designed and embedded into the main body of the ventilator. Flow measurements using a Venturi flowmeter were achieved successfully. Afterwards, a computational fluid dynamics study was carried out to estimate the flow behaviour at varying valve opening conditions. Also, a numerical noise prediction study was accomplished based on Broadband Noise Source Model. Finally, the effect of inlet pressure on flow rate was investigated with a parametric study, and required inlet pressure was determined. The results showed that the Venturi meter with a 4mm throat diameter at 0.5 bar inlet pressure condition satisfied the desired operating conditions.</p></abstract>
      <kwd-group kwd-group-type="author">
        <kwd>mechanical ventilator</kwd>
        <kwd>air/oxygen control unit</kwd>
        <kwd>COVID-19</kwd>
        <kwd>noise prediction</kwd>
        <kwd>computational fluid dynamics</kwd>
      </kwd-group>
      <conference>
        <conf-date>16 to 18 August 2022</conf-date>
        <conf-name>19th International Conference on Sustainable Energy Technologies</conf-name>
        <conf-acronym>SET2022</conf-acronym>
        <conf-num>19</conf-num>
        <conf-loc>Istanbul, Turkiye</conf-loc>
      </conference>
    </article-meta>
  </front>
  <body>
  </body>
  <back>
  </back>
</article>